For two-way data (data stemming from so-called hyphenated methods), several methods have been developed for quantification of analytes. One of the better known methods is rank annihilation factor analysis (RAFA). However, an effect observed in chromatographic data seriously reduces the usability of this method. Like any other method based on the use of standards, RAFA fails to estimate the correct concentrations in the presence of retention time shifts. Hence, a retention time shift correction method is necessary. Bessel's inequality can be used to adjust for the retention time shifting of the data relative to the standards. RAFA can then be used to estimate the concentrations with a high degree of precision. This procedure is demonstrated on four data sets of varying complexity, and is found to perform excellently for all sets.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 23 条
[1]   SIMPLEX FOCUSING OF RETENTION TIMES AND LATENT VARIABLE PROJECTIONS OF CHROMATOGRAPHIC PROFILES [J].
ANDERSSON, R ;
HAMALAINEN, MD .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 22 (01) :49-61
[2]   CORRECTION FOR FLUORESCENCE RESPONSE SHIFTS IN POLYAROMATIC HYDROCARBON MIXTURES WITH AN INNOVATIONS-BASED KALMAN FILTER METHOD [J].
CECIL, TL ;
RUTAN, SC .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1998-2004
[3]   QUANTIFICATION OF A KNOWN COMPONENT IN AN UNKNOWN MIXTURE [J].
GAMPP, H ;
MAEDER, M ;
MEYER, CJ ;
ZUBERBUEHLER, AD .
ANALYTICA CHIMICA ACTA, 1987, 193 :287-293
[4]   A PRIORI ESTIMATES OF THE ELUTION PROFILES OF THE PURE COMPONENTS IN OVERLAPPED LIQUID-CHROMATOGRAPHY PEAKS USING TARGET FACTOR-ANALYSIS [J].
GEMPERLINE, PJ .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1984, 24 (04) :206-212
[5]   APPLICATION OF THE METHOD OF RANK ANNIHILATION TO FLUORESCENT MULTICOMPONENT MIXTURES OF POLYNUCLEAR AROMATIC-HYDROCARBONS [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1980, 52 (07) :1071-1079
[6]   SIMULTANEOUS MULTICOMPONENT RANK ANNIHILATION AND APPLICATIONS TO MULTICOMPONENT FLUORESCENT DATA ACQUIRED BY THE VIDEO FLUOROMETER [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :92-98
[7]   APPLICATION OF METHOD OF RANK ANNIHILATION TO QUANTITATIVE-ANALYSES OF MULTICOMPONENT FLUORESCENCE DATA FROM VIDEO FLUOROMETER [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1108-1113
[8]   HEURISTIC EVOLVING LATENT PROJECTIONS - RESOLVING 2-WAY MULTICOMPONENT DATA .1. SELECTIVITY, LATENT-PROJECTIVE GRAPH, DATASCOPE, LOCAL RANK, AND UNIQUE RESOLUTION [J].
KVALHEIM, OM ;
LIANG, YZ .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :936-946
[9]   WHITE, GRAY AND BLACK MULTICOMPONENT SYSTEMS - A CLASSIFICATION OF MIXTURE PROBLEMS AND METHODS FOR THEIR QUANTITATIVE-ANALYSIS [J].
LIANG, YZ ;
KVALHEIM, OM ;
MANNE, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1993, 18 (03) :235-250
[10]   RESOLUTION OF STRONGLY OVERLAPPING 2-WAY MULTICOMPONENT DATA BY MEANS OF HEURISTIC EVOLVING LATENT PROJECTIONS [J].
LIANG, YZ ;
KVALHEIM, OM ;
RAHMANI, A ;
BRERETON, RG .
JOURNAL OF CHEMOMETRICS, 1993, 7 (01) :15-43