DOPPLER GUIDE-WIRE FLOW-VELOCITY INDEXES MEASURED DISTAL TO CORONARY STENOSES ASSOCIATED WITH REVERSIBLE THALLIUM PERFUSION DEFECTS

被引:65
作者
DEYCHAK, YA [1 ]
SEGAL, J [1 ]
REINER, JS [1 ]
ROHRBECK, SC [1 ]
THOMPSON, MA [1 ]
LUNDERGAN, CF [1 ]
ROSS, AM [1 ]
WASSERMAN, AG [1 ]
机构
[1] GEORGE WASHINGTON UNIV,MED CTR,DEPT MED,DIV CARDIOL,CARDIAC CATHETERIZAT LAB,WASHINGTON,DC 20037
关键词
D O I
10.1016/0002-8703(95)90001-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A Doppler guide wire was used to measure phasic coronary blood flow velocity distal to coronary stenoses in 17 symptomatic patients with corresponding positive exercise or adenosine thallium scintigrams. Distal average peak velocity and diastolic/systolic flow-velocity ratio were obtained in 16 vessels with stenoses (55% to 85% diameter stenosis) and a corresponding reversible thallium defect and in 11 control vessels with no stenosis or thallium defect. Coronary flow-velocity reserve was obtained with intracoronary adenosine. Coronary flow reserve (2.3 +/- 0.4 vs 1.2 +/- 0.3, p < 0.01) and diastolic/systolic flow-velocity ratio (1.95 +/- 0.56 vs 1.44 +/- 0.59, p < 0.04) were significantly different between normal vessels and distal to stenoses, respectively. Excellent concordance between distal coronary flow reserve and diastolic/systolic flow-velocity ratio to thallium scintigraphy was noted. A coronary flow reserve of <1.8 and a diastolic/systolic flow-velocity ratio of <1.7 predicted a reversible thallium perfusion scintigram (concordance 96% and 88%, respectively). Distal coronary flow velocity indexes may provide an alternative means of physiologic assessment of lesion severity during coronary angiography.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 1990, BASIC CLIN BIOSTATIS
[2]   PROGNOSIS WITH ABNORMAL THALLIUM IMAGES IN THE ABSENCE OF SIGNIFICANT CORONARY-ARTERY DISEASE [J].
CANNAN, CR ;
MILLER, TD ;
CHRISTIAN, TF ;
BAILEY, KR ;
GIBBONS, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (15) :1276-1280
[3]   Assessing the Hemodynamic Significance of Coronary Artery Stenoses: Analysis of Translesional Pressure-Flow Velocity Relations in Patients [J].
Donohue, Thomas J. ;
Kern, Morton J. ;
Aguirre, Frank V. ;
Bach, Richard G. ;
Wolford, Thomas ;
Bell, Calvin A. ;
Segal, Jerome .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :449-458
[4]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[5]  
FOLTS JD, 1975, CIRCULATION, V51, P148
[6]   COMPARISON OF CORONARY ARTERIOGRAMS WITH DIRECT MEASUREMENTS OF STENOSED CORONARY-ARTERIES IN DOGS [J].
GALLAGHER, KP ;
FOLTS, JD ;
ROWE, GG .
AMERICAN HEART JOURNAL, 1978, 95 (03) :338-347
[7]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[8]   THE VALUE OF LESION CROSS-SECTIONAL AREA DETERMINED BY QUANTITATIVE CORONARY ANGIOGRAPHY IN ASSESSING THE PHYSIOLOGIC SIGNIFICANCE OF PROXIMAL LEFT ANTERIOR DESCENDING CORONARY ARTERIAL STENOSES [J].
HARRISON, DG ;
WHITE, CW ;
HIRATZKA, LF ;
DOTY, DB ;
BARNES, DH ;
EASTHAM, CL ;
MARCUS, ML .
CIRCULATION, 1984, 69 (06) :1111-1119
[9]  
HELLER LI, 1993, CIRCULATION, V88, P204
[10]   INTRAVENOUS ADENOSINE - CONTINUOUS INFUSION AND LOW-DOSE BOLUS ADMINISTRATION FOR DETERMINATION OF CORONARY VASODILATOR RESERVE IN PATIENTS WITH AND WITHOUT CORONARY-ARTERY DISEASE [J].
KERN, MJ ;
DELIGONUL, U ;
TATINENI, S ;
SEROTA, H ;
AGUIRRE, F ;
HILTON, TC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) :718-729