SERIAL EXERCISE THALLIUM MYOCARDIAL PERFUSION SCANNING AND EXERCISE ELECTROCARDIOGRAPHY IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE

被引:24
作者
DUNN, RF
KELLY, DT
BAILEY, IK
UREN, R
MCLAUGHLIN, A
机构
[1] ROYAL PRINCE ALFRED HOSP,HALLSTROM INST CARDIOL,CAMPERDOWN 2050,NEW S WALES,AUSTRALIA
[2] ROYAL PRINCE ALFRED HOSP,DEPT NUCL MED,CAMPERDOWN 2050,NEW S WALES,AUSTRALIA
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE | 1979年 / 9卷 / 05期
关键词
D O I
10.1111/j.1445-5994.1979.tb03393.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Summary: Serial exercise thallium‐201 myocardial perfusion scanning (exercise and 4‐hour redistribution) was compared to rest and exercise electrocardiography (ECG) for the detection of coronary artery disease in 125 patients with known or suspected coronary artery disease. All patients underwent coronary arteriography and 108 were found to have significant coronary artery lesions. The serial exercise thallium scan was significantly more sensitive than rest and exercise ECG in detecting coronary artery disease (94% v. 83% P <0.01). The sensitivity of a reversible thallium perfusion scan abnormality and a positive exercise ECG for detecting exercise induced myocardial ischaemia in coronary artery disease was similar (69% v. 63%). The exercise thallium scan complemented the exercise EGG, and the sensitivity of the combined test was significantly greater than the exercise ECG alone (84% v. 63% P<0.001). The specificity for coronary artery disease of the exercise ECG was 65% and that of the exercise thallium‐201 myocardial perfusion scan was 82% (P = NS). Thallium‐201 myocardial perfusion scanning complements the rest and exercise ECG in the non‐invasive detection of coronary artery disease. Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:547 / 553
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 1975, CIRCULATION, V51, P5
[2]   TL-201 MYOCARDIAL PERFUSION IMAGING AT REST AND DURING EXERCISE - COMPARATIVE SENSITIVITY TO ELECTROCARDIOGRAPHY IN CORONARY-ARTERY DISEASE [J].
BAILEY, IK ;
GRIFFITH, LSC ;
ROULEAU, J ;
STRAUSS, HW ;
PITT, B .
CIRCULATION, 1977, 55 (01) :79-87
[3]  
BERMAN D, 1978, CIRCULATION, V58, P63
[4]   COMPARISON OF SINGLE-DOSE AND DOUBLE-DOSE TL-201 MYOCARDIAL PERFUSION SCINTIGRAPHY FOR DETECTION OF CORONARY-ARTERY DISEASE AND PRIOR MYOCARDIAL-INFARCTION [J].
BLOOD, DK ;
MCCARTHY, DM ;
SCIACCA, RR ;
CANNON, PJ .
CIRCULATION, 1978, 58 (05) :777-788
[5]   TL-201 MYOCARDIAL PERFUSION SCINTIGRAPHY FOR CLINICAL CLARIFICATION OF NORMAL, ABNORMAL AND EQUIVOCAL ELECTROCARDIOGRAPHIC STRESS TESTS [J].
BOTVINICK, EH ;
TARADASH, MR ;
SHAMES, DM ;
PARMLEY, WW .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (01) :43-51
[6]   MYOCARDIAL PERFUSION SCANNING WITH TL-201 FOR NON-INVASIVE DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DUNN, RF ;
BAILEY, IK ;
KELLY, DT ;
HUNG, J ;
UREN, R ;
BAUTOVICH, G ;
MCLAUGHLIN, A ;
MORRIS, JG .
MEDICAL JOURNAL OF AUSTRALIA, 1978, 2 (09) :441-444
[7]   INABILITY OF SUBMAXIMAL TREADMILL STRESS TEST TO PREDICT LOCATION OF CORONARY-DISEASE [J].
KAPLAN, MA ;
HARRIS, CN ;
ARONOW, WS ;
PARKER, DP ;
ELLESTAD, MH .
CIRCULATION, 1973, 47 (02) :250-256
[8]   DIAGNOSTIC ACCURACY OF SELECTIVE CORONARY CINEARTERIOGRAPHY [J].
KEMP, HG ;
EVANS, H ;
ELLIOTT, WC ;
GORLIN, R .
CIRCULATION, 1967, 36 (04) :526-&
[9]   MULTIPLE-LEAD EXERCISE ELECTROCARDIOGRAPHY - EXPERIENCE IN 107 NORMAL SUBJECTS AND 67 PATIENTS WITH ANGINA PECTORIS AND COMPARISON WITH CORONARY CINEARTERIOGRAPHY IN 84 PATIENTS [J].
MASON, RE ;
LIKAR, I ;
BIERN, RO ;
ROSS, RS .
CIRCULATION, 1967, 36 (04) :517-+
[10]   NOTE ON THE SAMPLING ERROR OF THE DIFFERENCE BETWEEN CORRELATED PROPORTIONS OR PERCENTAGES [J].
McNemar, Quinn .
PSYCHOMETRIKA, 1947, 12 (02) :153-157