Three-dimensional tissue motion and its effect on image noise in elastography

被引:65
作者
Kallel, F
Ophir, J
机构
[1] Ultrasonics Laboratory, Department of Radiology, University of Texas Medical School, Houston
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.656632
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In elastography both high correlation coefficient between pre-and post-compression RF signals and high applied strain are required to achieve the best quality in elastograms. Because the elastogram is computed using a 1-D cross-correlation technique applied to a 1-D ultrasound signal, it is assumed that tissue motion occurs only within the axis of compression (axis of the acoustic wave propagation), or at least that the scatterers remain within the acoustic beam during tissue motion, In practice, soft tissues are incompressible and, therefore, the lateral and elevational (out-of-plane) tissue strains are 50% of the applied strain, Therefore, tissue scatterers may move across the beam due to the applied compression, In this paper we address the degradation of the elastographic quality due to the lateral and elevational motion of the scatterers in uniformly elastic media, A full 3-D model predicting the correlation coefficient as measured using 1-D cross-correlations is proposed. It is shown that the signal-to-noise ratio in elastograms (SNRe) is nonstationary, and that it depends on the beamwidth and on the applied strain, In order to achieve a higher stationary SNRe, it is proposed to confine the tissue in the lateral direction. Phantom experiments are used to corroborate the theoretical developments.
引用
收藏
页码:1286 / 1296
页数:11
相关论文
共 35 条
[1]   Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography [J].
Alam, SK ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :95-105
[2]  
ANDERSON WAD, 1953, PATHOLOGY
[3]   EFFECTIVE DIRECTIVITY CHARACTERISTIC OF A PULSED ULTRASOUND TRANSDUCER AND ITS MEASUREMENT BY SEMIAUTOMATIC MEANS [J].
BAMBER, J ;
PHELPS, J .
ULTRASONICS, 1977, 15 (04) :169-174
[4]   LESION DETECTION IN SIMULATED ELASTOGRAPHIC AND ECHOGRAPHIC IMAGES - A PSYCHOPHYSICAL STUDY [J].
BELAID, N ;
CESPEDES, I ;
THIJSSEN, JM ;
OPHIR, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :877-891
[5]   Error analysis in acoustic elastography .2. Strain estimation and SNR analysis [J].
Bilgen, M ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) :1147-1154
[6]   Error analysis in acoustic elastography .1. Displacement estimation [J].
Bilgen, M ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) :1139-1146
[7]  
Carter G.C., 1993, COHERENCE TIME DELAY
[8]  
CESPEDES EI, 1997, IEEE T ULTRASON FERR, V44, P220
[9]  
CESPEDES I, 1993, THESIS U HOUSTON HOU
[10]  
CESPEDES IE, 1995, IEEE T ULTRASON FERR, V24, P969