A fully automated comparative microaneurysm digital detection system

被引:107
作者
Cree, MJ
Olson, JA
McHardy, KC
Sharp, PF
Forrester, JV
机构
[1] ABERDEEN ROYAL INFIRM,EYE CLIN,ABERDEEN,SCOTLAND
[2] ABERDEEN ROYAL INFIRM,DIABET CLIN,ABERDEEN,SCOTLAND
[3] UNIV ABERDEEN,DEPT OPHTHALMOL,ABERDEEN,SCOTLAND
关键词
D O I
10.1038/eye.1997.166
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A fully automated digital image processing system, which provides an objective and repeatable way to quantify microaneurysms in digitised fluorescein angiograms, has been developed, The automated computer processing includes registration of same-eye retinal images for serial studies, cutting of regions-of-interest centred on the fovea, the detection of microaneurysms and the comparison of serial images for microaneurysm turnover, The microaneurysm detector was trained against a database of 68 images of patients with diabetes containing 394 true microaneurysms, as identified by an ophthalmologist, The microaneurysm detector achieved 82% sensitivity with 2.0 false-positives per image. An independent test set, comprising 20 images containing 297 true microaneurysms, was used to compare the microaneurysm detector with clinicians, The microaneurysm detector achieved a sensitivity of 82% for 5.7 false-positives per image, whereas the clinician receiver-operator-characteristic (ROC) curve gives 3.2 false-positives per image at a sensitivity of 82%, It is concluded that the computer system can reliably detect microaneurysms, The advantages of the computer system include objectivity, repeatability, speed and full automation.
引用
收藏
页码:622 / 628
页数:7
相关论文
共 9 条
[1]  
CIDECIYAN AV, 1992, P SOC PHOTO-OPT INS, V1652, P310, DOI 10.1117/12.59439
[2]  
FRAME AJ, 1996, P 2 INT C NEUR NETW, P50
[3]   THE RELATIONSHIP OF RETINAL MICROANEURYSM COUNTS TO THE 4-YEAR PROGRESSION OF DIABETIC-RETINOPATHY [J].
KLEIN, R ;
MEUER, SM ;
MOSS, SE ;
KLEIN, BEK .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (12) :1780-1785
[4]  
KOHNER EM, 1986, OPHTHALMOLOGY, V93, P586
[5]   RATE OF FORMATION AND DISAPPEARANCE OF MICROANEURYSMS IN DIABETIC RETINOPATHY [J].
KOHNER, EM ;
DOLLERY, CT .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1970, 1 (03) :167-&
[6]  
LAY B, 1983, P SOC PHOTO-OPT INST, V432, P165
[7]  
METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
[8]   Image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus [J].
Spencer, T ;
Olson, JA ;
McHardy, KC ;
Sharp, PF ;
Forrester, JV .
COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (04) :284-302
[9]   AUTOMATED DETECTION AND QUANTIFICATION OF MICROANEURYSMS IN FLUORESCEIN ANGIOGRAMS [J].
SPENCER, T ;
PHILLIPS, RP ;
SHARP, PF ;
FORRESTER, JV .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (01) :36-41