Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction

被引:214
作者
Bhagavan, NV
Lai, EM
Rios, PA
Yang, JS
Ortega-Lopez, AM
Shinoda, H
Honda, SAA
Rios, CN
Sugiyama, CE
Ha, CE
机构
[1] Univ Hawaii, John A Burns Sch Med, Dept Biochem & Biophys, Honolulu, HI 96822 USA
[2] Univ Hawaii, John A Burns Sch Med, Dept Pathol, Integrated Pathol Residency Program, Honolulu, HI 96822 USA
[3] Univ Hawaii, John A Burns Sch Med, Dept Med, Integrated Med Residency Program, Honolulu, HI 96822 USA
[4] Kaiser Fdn Hosp, Dept Pathol, Honolulu, HI USA
关键词
D O I
10.1373/49.4.581
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Clinical diagnoses were correlated with results of a Co(II)-albumin binding assay in 167 patients treated at an emergency department of a health maintenance organization. Methods: Patients were evaluated as being nonischemic or potentially ischemic through standard coronary disease indicators [creatine kinase (CK), CK-MB, cardiac troponin I, and electrocardiographic findings] and were tested by a Co(II)-albumin binding assay. Samples were tested anonymously, and the study was double-blinded. The sensitivity and specificity of this assay for the detection of ischemia were evaluated by ROC curve analysis. Known Co(II) binding sites. on albumin were analyzed by N-terminal amino acid sequencing. Results: The mean absorbance units (ABSU) +/- 2 SD for non-myocardial ischemic and myocardial ischemic individuals measured at 470 nm were 0.43 +/- 0.10 and 0.63 +/- 0.25, respectively (P <0.0001). The area under the ROC curve. was 0.95 [95 % confidence. interval (CI), 0.92-0.99], and at a cutoff value of .0.50 ABSU, sensitivity and specificity were 88% (78-94%) and 94% (86-98%), respectively, suggesting a high distinction between the two groups. When we compared non-acute myocardial infarction (AMI) and AMI ischemic individuals, the area under the ROC curve was 0.66 (95% CI, 0.53-0.79) and was considered a poor discriminator between these two groups. N-Terminal amino acid sequencing data for purified albumin showed normal amino acid residues for six of seven high-ABSU (≥0.70) individuals and one nonischemic individual tested. However, only one individual with a high ABSU (0.80) had two missing amino acid residues (DA) from the N-terminal region. Clinical diagnosis for this patient did not reveal an ischemic event. Conclusions: The Co(II)-albumin binding test may serve as a useful diagnostic tool in emergency facilities for the assessment of myocardial ischemia. High and low ABSU were associated with myocardial ischemic individuals and non-myocardial ischemic individuals, respectively. However, the Co(II)-albumin binding was a poor discriminator between ischemic individuals with and without MI. (C) 2003 American Association for Clinical Chemistry.
引用
收藏
页码:581 / 585
页数:5
相关论文
共 14 条
[1]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[2]   A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia - A preliminary report [J].
Bar-Or, D ;
Lau, E ;
Winkler, JV .
JOURNAL OF EMERGENCY MEDICINE, 2000, 19 (04) :311-315
[3]   Reduced albumin-cobalt binding with transient myocardial ischemia after elective percutaneous transluminal coronary angioplasty: A preliminary comparison to creatine kinase-MB, myoglobin, and troponin I [J].
Bar-Or, D ;
Winkler, JV ;
VanBenthuysen, K ;
Harris, L ;
Lau, E ;
Hetzel, FW .
AMERICAN HEART JOURNAL, 2001, 141 (06) :985-991
[4]   Characterization of the Co2+ and Ni2+ binding amino-acid residues of the N-terminus of human albumin -: An insight into the mechanism of a new assay for myocardial ischemia [J].
Bar-Or, D ;
Curtis, G ;
Rao, N ;
Bampos, N ;
Lau, E .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 2001, 268 (01) :42-47
[5]   CHARACTERIZATION OF A SLOW COMPONENT OF NORMAL HUMAN-SERUM ALBUMIN [J].
BRENNAN, SO ;
GEORGE, PM ;
PEACH, RJ .
CLINICA CHIMICA ACTA, 1988, 176 (02) :179-184
[6]   SITE-SPECIFIC N-TERMINAL AUTO-DEGRADATION OF HUMAN SERUM-ALBUMIN [J].
CHAN, B ;
DODSWORTH, N ;
WOODROW, J ;
TUCKER, A ;
HARRIS, R .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1995, 227 (1-2) :524-528
[7]  
Christenson RH, 2001, CLIN CHEM, V47, P464
[8]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[9]   CHARACTERIZATION OF THE COPPER(II)-TRANSPORT AND NICKEL(II)-TRANSPORT SITE OF HUMAN-SERUM ALBUMIN - STUDIES OF COPPER(II) AND NICKEL(II) BINDING TO PEPTIDE 1-24 OF HUMAN-SERUM ALBUMIN BY C-13 AND H-1-NMR SPECTROSCOPY [J].
LAUSSAC, JP ;
SARKAR, B .
BIOCHEMISTRY, 1984, 23 (12) :2832-2838
[10]   EARLY DETECTION OF ACUTE MYOCARDIAL-INFARCTION BY MEASUREMENT OF MASS CONCENTRATION OF CREATINE KINASE-MB [J].
MAIR, J ;
ARTNERDWORZAK, E ;
DIENSTL, A ;
LECHLEITNER, P ;
MORASS, B ;
SMIDT, J ;
WAGNER, I ;
WETTACH, C ;
PUSCHENDORF, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (17) :1545-1550