Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas

被引:103
作者
Farre, R
Montserrat, JM
Rotger, M
Ballester, E
Navajas, D
机构
[1] Univ Barcelona, Fac Med, Lab Biofis & Bioengn, E-08036 Barcelona, Spain
[2] Hosp Clin Barcelona, Serv Pneumol, Barcelona, Spain
关键词
airflow measurement; hypopnoea; monitoring; pneumotachograph; sleep apnoea syndrome; thermally sensitive devices;
D O I
10.1183/09031936.98.11010179
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th, V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow. V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 12 条
[1]  
[Anonymous], 1989, AM REV RESPIR DIS, V139, P559
[2]  
DOEBELIN EO, 1990, MEASUREMENT SYSTEMS, P692
[3]   A system to generate simultaneous forced oscillation and continuous positive airway pressure [J].
Farre, R ;
Rotger, M ;
Montserrat, JM ;
Navajas, D .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (06) :1349-1353
[4]   RESPIRATORY MONITORING IN SLEEP-APNEA SYNDROME [J].
LEVY, P ;
PEPIN, JL ;
WUYAM, B ;
VEALE, D .
SLEEP, 1992, 15 (06) :S5-S8
[5]   TIME-COURSE OF STEPWISE CPAP TITRATION - BEHAVIOR OF RESPIRATORY AND NEUROLOGICAL VARIABLES [J].
MONTSERRAT, JM ;
BALLESTER, E ;
OLIVI, H ;
REOLID, A ;
LLOBERES, P ;
MORELLO, A ;
RODRIGUEZROISIN, R .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (06) :1854-1859
[6]   Evaluation of nasal prongs for estimating nasal flow [J].
Montserrat, JM ;
Farre, R ;
Ballester, E ;
Felez, MA ;
Pasto, M ;
Navajas, D .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (01) :211-215
[7]   RESPIRATORY INPUT IMPEDANCE DURING HIGH-FREQUENCY OSCILLATORY VENTILATION [J].
NAVAJAS, D ;
FARRE, R .
BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 :S85-S90
[8]  
Pasto M., 1996, European Respiratory Journal Supplement, V9, p196S
[9]  
Pasto M., 1995, European Respiratory Journal, V8, p253S
[10]   Heat transfer evaluation of the nasal thermistor technique [J].
Storck, K ;
Karlsson, M ;
Ask, P ;
Loyd, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (12) :1187-1191