Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution

被引:82
作者
Balik, M
Pachl, J
Hendl, J
机构
[1] Univ Hosp Kralovske Vinohrody, Dept Intens Care & Anesthesia, Prague 10034 10, Czech Republic
[2] Charles Univ, Fac Phys Educ & Sport, Dept Kinanthropol, Prague, Czech Republic
关键词
tricuspid regurgitation; cardiac output; echocardiography; Doppler ultrasonography; pulmonary artery catheter; thermodilution;
D O I
10.1007/s00134-002-1352-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the relationship between the degree of tricuspid regurgitation (TR) and accuracy of cardiac output measurement by thermodilution in mechanically ventilated patients. Design and setting: Prospective observational study in a 20-bed general intensive care unit in the university hospital. Patients: We examined 27 patients (not undergoing cardiac surgery): 8 with no or 1st degree TR, 9 with 2nd degree, and 10 with 3rd degree TR. Interventions: All patients were measured twice using simultaneously transesophageal echocardiography and pulmonary artery catheter for cardiac output. Measurements and results: Continuous Doppler measurements were taken in the left ventricular outflow tract at the level of the aortic valve. Cardiac output was calculated by multiplying the velocity-time integral by aortic valve area and heart rate. Simultaneous pulmonary artery catheter measurements were taken averaging the results of the three 10-cc boluses of iced saline. The difference between the methods was 0.5+/-1.1 l/min (mean +/- 2 SD) in patients with no or 1st degree TR (r=0.96), 0.8 2.0 l/min in those with 2nd degree TR (r=0.92), and 1.9+/-2.3 l/min in those with 3rd degree TR (r=0.69). Conclusions: A high degree of TR is associated with underestimation of cardiac output measured by thermodilution.
引用
收藏
页码:1117 / 1121
页数:5
相关论文
共 20 条
[1]   PEEP-induced tricuspid regurgitation [J].
Artucio, H ;
Hurtado, J ;
Zimet, L ;
dePaula, J ;
Beron, M .
INTENSIVE CARE MEDICINE, 1997, 23 (08) :836-840
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
DARMON PL, 1994, ANESTHESIOLOGY, V80, P796, DOI 10.1097/00000542-199404000-00011
[4]   Optimal number of beats for the Doppler measurement of cardiac output in atrial fibrillation [J].
Dubrey, SW ;
Falk, RH .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (01) :67-71
[5]   Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients - Comparison with thermodilution [J].
Estagnasie, P ;
Djedaini, K ;
Mier, L ;
Coste, F ;
Dreyfuss, D .
INTENSIVE CARE MEDICINE, 1997, 23 (07) :753-759
[6]   INCIDENCE OF TRICUSPID REGURGITATION AND VENA-CAVAL BACKWARD FLOW IN MECHANICALLY VENTILATED PATIENTS - A COLOR DOPPLER AND CONTRAST ECHOCARDIOGRAPHIC STUDY [J].
JULLIEN, T ;
VATIER, B ;
HONGNAT, JM ;
DUBOURG, O ;
BOURDARIAS, JP ;
JARDIN, F .
CHEST, 1995, 107 (02) :488-493
[7]  
Luchette FA, 2000, J INVEST SURG, V13, P147
[8]  
MARSHALL SA, 1994, PRINCIPLES PRACTICE, P955
[9]  
McCloy K, 1999, Am J Crit Care, V8, P86
[10]   Estimation of cardiac output by noninvasive echocardiographic techniques in the critically ill subject [J].
McLean, AS ;
Needham, A ;
Stewart, D ;
Parkin, R .
ANAESTHESIA AND INTENSIVE CARE, 1997, 25 (03) :250-254