Steady-state and dynamic MR angiography with MS-325: Initial experience in humans

被引:198
作者
Grist, TM
Korosec, FR
Peters, DC
Witte, S
Walovitch, RC
Dolan, RP
Bridson, WE
Yucel, EK
Mistretta, CA
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Phys Med, Madison, WI 53792 USA
[3] Corning Besselaar Clin Res Unit, Madison, WI USA
关键词
arteries; MR; contrast media; experimental studies; gadolinium; iron; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.207.2.9577507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the imaging performance and patient tolerance of a blood-pool contrast agent (MS-325) for magnetic resonance (MR) angiography. MATERIALS AND METHODS: Imaging of peripheral and carotid vessels was performed in seven healthy volunteers in a phase I clinical trial of the gadolinium chelate MS-325. Each volunteer received an intravenous injection of 0.05 mmol/kg MS-325 over 30 seconds. Dynamic (arterial phase) and steady-state (arterial-venous phase) three-dimensional gradient-echo MR angiograms were acquired during, immediately after, and approximately 50 minutes after injection. Images were ranked (1 [poor] to 5 [excellent]) for overall image quality, and signal-to-noise ratio (S/N) and contrast-to-noise ratio (C/N) were measured by using standard techniques. RESULTS: All volunteers tolerated the procedure well. The MS-325-enhanced studies demonstrated intense vascular signal. Mean peripheral arterial C/N was 12.9 +/- 4.8 (standard deviation), 78.8 +/- 29.4, 46.1 +/- 10.9, and 41.9 +/- 14.1 for the two-dimensional (2D) time-of-flight (TOF) and the contrast material-enhanced dynamic, early steady-state, and late steady-state images, respectively. Image quality of steady-state postcontrast images was statistically significantly (P < .02) higher than that of 2D TOF images. Image quality of early and late postcontrast images was similar, but a small (10%) decrease in C/N was noted from early to late images. CONCLUSION: MS-325 provides excellent vascular and selective arterial enhancement during dynamic MR angiography. The long blood residence time also allows acquisition of steady-state images of the arteries and veins with excellent spatial resolution.
引用
收藏
页码:539 / 544
页数:6
相关论文
共 11 条
[1]  
*ACR, 1995, ACR TASK FORC APPR C
[2]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[3]   MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent [J].
Anzai, Y ;
Prince, MR ;
Chenevert, TL ;
Maki, JH ;
Londy, F ;
London, M ;
McLachlan, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :209-214
[4]   Human aorta: Preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets [J].
Davis, CP ;
Ladd, ME ;
Romanowski, BJ ;
Wildermuth, S ;
Knoplioch, JF ;
Debatin, JF .
RADIOLOGY, 1996, 199 (01) :37-40
[5]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[6]   Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging [J].
Krinsky, GA ;
Rofsky, NM ;
DeCorato, DR ;
Weinreb, JC ;
Earls, JP ;
Flyer, MA ;
Galloway, AC ;
Colvin, SB .
RADIOLOGY, 1997, 202 (01) :183-193
[7]  
LAUFFER R, 1997, RADIOLOGY, V207, P529
[8]  
LEUNG DA, 1996, RADIOLOGY, V201, P569
[9]   Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries [J].
Levy, RA ;
Prince, MR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :211-215
[10]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881