Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest

被引:927
作者
Abella, BS
Alvarado, JP
Myklebust, H
Edelson, DP
Barry, A
O'Hearn, N
Vanden Hoek, TL
Becker, LB
机构
[1] Univ Chicago Hosp, Sect Emergency Med, Chicago, IL 60637 USA
[2] Univ Chicago Hosp, Sect Crit Care, Chicago, IL 60637 USA
[3] Laerdal Med Corp, Stavanger, Norway
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 2005年 / 293卷 / 03期
关键词
D O I
10.1001/jama.293.3.305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context The survival benefit of well-performed cardiopulmonary resuscitation (CPR) is well-documented, but little objective data exist regarding actual CPR quality during cardiac arrest. Recent studies have challenged the notion that CPR is uniformly performed according to established international guidelines. Objectives To measure multiple parameters of in-hospital CPR quality and to determine compliance with published American Heart Association and international guidelines. Design and Setting A prospective observational study of 67 patients who experienced in-hospital cardiac arrest at the University of Chicago Hospitals, Chicago, III, between December 11, 2002, and April 5, 2004. Using a monitor/defibrillator with novel additional sensing capabilities, the parameters of CPR quality including chest compression rate, compression depth, ventilation rate, and the fraction of arrest time without chest compressions (no-flow fraction) were recorded. Main Outcome Measure Adherence to American Heart Association and international CPR guidelines. Results Analysis of the first 5 minutes of each resuscitation by 30-second segments revealed that chest compression rates were less than 90/min in 28.1% of segments. Compression depth was too shallow (defined as <38 mm) for 37.4% of compressions. Ventilation rates were high, with 60.9% of segments containing a rate of more than 20/min. Additionally, the mean (SD) no-flow fraction was 0.24 (0.18). A 10-second pause each minute of arrest would yield a no-flow fraction of 0.17. A total of 27 patients (40.3%) achieved return of spontaneous circulation and 7 (10.4%) were discharged from the hospital. Conclusions In this study of in-hospital cardiac arrest, the quality of multiple parameters of CPR was inconsistent and often did not meet published guideline recommendations, even when performed by well-trained hospital staff. The importance of high-quality CPR suggests the need for rescuer feedback and monitoring of CPR quality during resuscitation efforts.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 36 条
[1]   CPR artifact removal from human ECG using optimal multichannel filtering [J].
Aase, SO ;
Eftestol, T ;
Husoy, JH ;
Sunde, K ;
Steen, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (11) :1440-1449
[2]   Compression depth estimation for CPR quality assessment using DSP on accelerometer signals [J].
Aase, SO ;
Myklebust, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (03) :263-268
[3]  
ABELLA BS, IN PRESS CIRCULATION
[4]  
[Anonymous], 2000, RESUSCITATION, V46, P1
[5]   Hyperventilation-induced hypotension during cardiopulmonary resuscitation [J].
Aufderheide, TP ;
Sigurdsson, G ;
Pirrallo, RG ;
Yannopoulos, D ;
McKnite, S ;
von Briesen, C ;
Sparks, CW ;
Conrad, CJ ;
Provo, TA ;
Lurie, KG .
CIRCULATION, 2004, 109 (16) :1960-1965
[6]  
Becker LB, 1996, CARDIAC ARREST SCI P, P28
[7]   Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest [J].
Berg, RA ;
Sanders, AB ;
Kern, KB ;
Hilwig, RW ;
Heidenreich, JW ;
Porter, ME ;
Ewy, GA .
CIRCULATION, 2001, 104 (20) :2465-2470
[8]   HAWTHORNE EFFECT - IMPLICATIONS FOR PREHOSPITAL RESEARCH [J].
CAMPBELL, JP ;
MAXEY, VA ;
WATSON, WA .
ANNALS OF EMERGENCY MEDICINE, 1995, 26 (05) :590-594
[9]   Influence of cardiopulmonary resuscitation prior to defibrillation in patients with out-of-hospital ventricular fibrillation [J].
Cobb, LA ;
Fahrenbruch, CE ;
Walsh, TR ;
Copass, MK ;
Olsufka, M ;
Breskin, M ;
Hallstrom, AP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (13) :1182-1188
[10]   A comparison of manikin CPR performance by lay persons trained in three variations of basic life support guidelines [J].
Donnelly, P ;
Assar, D ;
Lester, C .
RESUSCITATION, 2000, 45 (03) :195-199