An optimized protocol for metabolome analysis in yeast using direct infusion electrospray mass spectrometry

被引:160
作者
Castrillo, JI
Hayes, A
Mohammed, S
Gaskell, SJ
Oliver, SG
机构
[1] Univ Manchester, Sch Biol Sci, Manchester M13 9PT, Lancs, England
[2] Univ Manchester, Dept Chem, Michael Barber Ctr Mass Spectrometry, Manchester M60 1QD, Lancs, England
基金
英国生物技术与生命科学研究理事会;
关键词
yeast; quenching and extraction method; intracellular metabolite analysis; electrospray mass spectrometry (ES-MS); direct infusion; metabolic profiles; metabolic fingerprinting; metabolome; metabolomics; functional genomics;
D O I
10.1016/S0031-9422(02)00713-6
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A method for the global analysis of yeast intracellular metabolites, based on electrospray mass spectrometry (ES-MS), has been developed. This has involved the optimization of methods for quenching metabolism in Saccharomyces cerevisiae and extracting the metabolites for analysis by positive-ion electrospray mass spectrometry. The influence of cultivation conditions, sampling, quenching and extraction conditions, concentration step, and storage have all been studied and adapted to allow direct infusion of samples into the mass spectrometer and the acquisition of metabolic profiles with simultaneous detection of more than 25 intracellular metabolites. The method, which can be applied to other micro-organisms and biological systems, may be used for comparative analysis and screening of metabolite profiles of yeast strains and mutants under controlled conditions in order to elucidate gene function via metabolomics. Examples of the application of this analytical strategy to specific yeast strains and single-ORF yeast deletion mutants generated through the EUROFAN programme are presented. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:929 / 937
页数:9
相关论文
共 52 条
[1]  
Baganz F, 1997, YEAST, V13, P1563, DOI 10.1002/(SICI)1097-0061(199712)13:16<1563::AID-YEA240>3.0.CO
[2]  
2-6
[3]  
Baganz F, 1998, YEAST, V14, P1417, DOI 10.1002/(SICI)1097-0061(199811)14:15<1417::AID-YEA334>3.3.CO
[4]  
2-E
[5]   SINGLE-RUN SEPARATION AND DETECTION OF MULTIPLE METABOLIC INTERMEDIATES BY ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND APPLICATION TO CELL POOL EXTRACTS PREPARED FROM ESCHERICHIA-COLI [J].
BHATTACHARYA, M ;
FUHRMAN, L ;
INGRAM, A ;
NICKERSON, KW ;
CONWAY, T .
ANALYTICAL BIOCHEMISTRY, 1995, 232 (01) :98-106
[6]  
Brachmann CB, 1998, YEAST, V14, P115
[7]   Quantification of intracellular metabolites in Escherichia coli K12 using liquid chromatographic-electrospray ionization tandem mass spectrometric techniques [J].
Buchholz, A ;
Takors, R ;
Wandrey, C .
ANALYTICAL BIOCHEMISTRY, 2001, 295 (02) :129-137
[8]  
Chatterjee MT, 2001, YEAST, V18, P81, DOI 10.1002/1097-0061(200101)18:1<81::AID-YEA666>3.0.CO
[9]  
2-3
[10]   A METHOD FOR THE DETERMINATION OF CHANGES OF GLYCOLYTIC METABOLITES IN YEAST ON A SUBSECOND TIME SCALE USING EXTRACTION AT NEUTRAL PH [J].
DEKONING, W ;
VANDAM, K .
ANALYTICAL BIOCHEMISTRY, 1992, 204 (01) :118-123