A status report on free-response analysis

被引:15
作者
Chakraborty, D. P. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
基金
美国国家卫生研究院;
关键词
OBSERVER-PERFORMANCE; FROC CURVES; LOCALIZATION; METHODOLOGY; VALIDATION; MODEL;
D O I
10.1093/rpd/ncp305
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this paper is to summarise recent progress in free-response receiver operating characteristic (FROC) methodology. These are: (1) jackknife alternative FROC analysis including recent extensions and alternative methods; (2) the search-model simulator that enables validation and objective comparison of different methods of analysing the data; (3) case-based analysis that has the potential of greater clinical relevance than conventional free-response analysis; (4) a method for collectively analysing the multiple lesion types in an image (e.g. microcalcifications, masses and architectural distortions); (5) a method for sample-size estimation for FROC studies; and (6) a method for determining an objective proximity criterion, namely how close must a mark be to a true lesion in order to credit the observer for a true localisation. FROC analysis is being increasingly used to evaluate the imaging systems and understanding of recent progress should help researchers conduct better FROC studies.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 27 条
[1]   Ambient lighting: Effect of illumination on soft-copy viewing of radiographs of the wrist [J].
Brennan, Patrick C. ;
McEntee, Mark ;
Evanoff, Michael ;
Phillips, Peter ;
O'Connor, William T. ;
Manning, David J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :W177-W180
[2]  
BUNCH PC, 1978, J APPL PHOTOGR ENG, V4, P166
[3]   ROC curves predicted by a model of visual search [J].
Chakraborty, D. P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :3463-3482
[4]   A search model and figure of merit for observer data acquired according to the free-response paradigm [J].
Chakraborty, D. P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :3449-3462
[5]   JAFROC analysis revisited: figure-of-merit considerations for human observer studies [J].
Chakraborty, D. P. ;
Yoon, Hong-Jun .
MEDICAL IMAGING 2009: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2009, 7263
[6]   Spatial localization accuracy of radiologists in free-response studies: Inferring perceptual FROC curves from mark-rating data [J].
Chakraborty, Dev ;
Yoon, Hong-Jun ;
Mello-Thoms, Claudia .
ACADEMIC RADIOLOGY, 2007, 14 (01) :4-18
[7]   Validation and Statistical Power Comparison of Methods for Analyzing Free-response Observer Performance Studies [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2008, 15 (12) :1554-1566
[8]   Observer studies involving detection and localization: Modeling, analysis, and validation [J].
Chakraborty, DP ;
Berbaum, KS .
MEDICAL PHYSICS, 2004, 31 (08) :2313-2330
[9]   MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1989, 16 (04) :561-568
[10]   FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881