Determination of acidic herbicides using liquid chromatography with pneumatically assisted electrospray ionization mass spectrometric and tandem mass spectrometric detection

被引:74
作者
Koppen, B [1 ]
Spliid, NH [1 ]
机构
[1] Natl Environm Res Inst, Dept Environm Chem, DK-4000 Roskilde, Denmark
关键词
mass spectrometry; pesticides; phenoxy acids; sulfonylureas; phenols;
D O I
10.1016/S0021-9673(97)01219-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-pneumatically assisted electrospray mass spectrometry with negative ionization has been used for the determination of acidic herbicides in ground water. Eighteen pesticides or pesticide degradation products belonging to several different groups of acidic herbicides (phenoxy acids, sulfonylureas, phenols, etc.) were covered in the study. Optimization of electrospray inlet conditions is described as well as results from investigations of the linearity of the detector response. Conditions for tandem mass spectrometry (MS-MS) detection of characteristic daughter ions formed by collision-induced dissociation (CID) of the parent ion are described and a comparison of obtainable instrument detection limits by single MS and MS-MS was made. Detection limits using MS in the selected ion monitoring (SIM) mode were generally in the order of 1 mu g/l or below, whereas detection limits were three-four times higher using MS-MS detection. A principle of analysis is proposed based on single quadrupole MS as a method for quantitative determination followed by verification of positive findings by CID MS-MS. Application of the method for detecting acidic herbicides residues in a "real-world" ground water sample is demonstrated. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:157 / 168
页数:12
相关论文
共 10 条
[1]   DETERMINATION OF THE PESTICIDE DIFLUBENZURON IN MUSHROOMS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
BARNES, KA ;
STARTIN, JR ;
THORPE, SA ;
REYNOLDS, SL ;
FUSSELL, RJ .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :85-93
[2]   AUTOMATED ONLINE LIQUID-SOLID EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-HIGH-FLOW PNEUMATICALLY ASSISTED ELECTROSPRAY MASS-SPECTROMETRY FOR THE DETERMINATION OF ACIDIC HERBICIDES IN ENVIRONMENTAL WATERS [J].
CHIRON, S ;
PAPILLOUD, S ;
HAERDI, W ;
BARCELO, D .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1637-1643
[3]   DETERMINATION OF ACIDIC PESTICIDES IN WATER BY A BENCHTOP ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETER [J].
CRESCENZI, C ;
DICORCIA, A ;
MARCHESE, S ;
SAMPERI, R .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1968-1975
[4]   Single short-column liquid chromatography with atmospheric pressure chemical ionization (tandem) mass spectrometric detection for trace environmental analysis [J].
Hogenboom, AC ;
Slobodnik, J ;
Vreuls, JJ ;
Rontree, JA ;
vanBaar, BLM ;
Niessen, WMA ;
Brinkman, UAT .
CHROMATOGRAPHIA, 1996, 42 (9-10) :506-514
[5]   Determination of parts per trillion levels of organophosphorus pesticides in groundwater by automated on-line liquid-solid extraction followed by liquid chromatography atmospheric pressure chemical ionization mass spectrometry using positive and negative ion modes of operation [J].
Lacorte, S ;
Barcelo, D .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2464-2470
[6]   COLUMN LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - SELECTED TECHNIQUES IN ENVIRONMENTAL APPLICATIONS FOR POLAR PESTICIDES AND RELATED-COMPOUNDS [J].
SLOBODNIK, J ;
VANBAAR, BLM ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :81-121
[7]   Trace-level determination of pesticide residues using on-line solid-phase extraction-column liquid chromatography with atmospheric pressure ionization mass spectrometric and tandem mass spectrometric detection [J].
Slobodnik, J ;
Hogenboom, AC ;
Vreuls, JJ ;
Rontree, JA ;
vanBaar, BLM ;
Niessen, WMA ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (01) :59-74
[8]  
Spliid NH, 1996, J CHROMATOGR A, V736, P105
[9]   LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY MULTIRESIDUE DETERMINATION OF SULFONYLUREAS AFTER ONLINE TRACE ENRICHMENT [J].
VOLMER, D ;
WILKES, JG ;
LEVSEN, K .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (09) :767-771
[10]   NEGATIVE-ION MASS-SPECTROMETRY OF SULFONYLUREA HERBICIDES [J].
WINNIK, W ;
BRUMLEY, W ;
BETOWSKI, L .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (11) :1574-1580