Implementation of laser-induced breakdown spectroscopy as a continuous emissions monitor for toxic metals

被引:105
作者
Buckley, SG [1 ]
Johnsen, HA [1 ]
Hencken, KR [1 ]
Hahn, DW [1 ]
机构
[1] Sandia Natl Labs, Livermore, CA 94551 USA
关键词
laser-induced breakdown spectroscopy (LIBS); toxic metals; continuous emission monitor;
D O I
10.1016/S0956-053X(00)00011-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) has been considered for some time as a potential CEM method for toxic metals. Recently, improvements in sampling methodology and signal processing have allowed LIES to achieve detection limits below the proposed MACT limits for 5 out of 6 of the RCRA metals. This paper discusses performance improved by nearly 2 orders of magnitude of this in situ monitoring technique following implementation of conditional analysis. Results from trial burns at two incinerators and at a DoD contained burn facility are highlighted. At the incinerators, implementation of conditional analysis yielded much lower detection limits than previously reported using the LIBS technique. At the contained burn facility, reproducible, transient Pb measurements were recorded in real-time for concentration values that varied by more than two orders of magnitude. Method detection limits of between 2 and 100 mu g/dscm are reported for toxic metals Be, Cd, Cr, He, and Pb. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 9 条
[1]   Discrete particle detection and metal emissions monitoring using laser-induced breakdown spectroscopy [J].
Hahn, DW ;
Flower, WL ;
Hencken, KR .
APPLIED SPECTROSCOPY, 1997, 51 (12) :1836-1844
[2]   Laser-induced breakdown spectroscopy for sizing and elemental analysis of discrete aerosol particles [J].
Hahn, DW .
APPLIED PHYSICS LETTERS, 1998, 72 (23) :2960-2962
[3]  
HAHN DW, UNPUB TEMPORAL GATIN
[4]   REVIEW OF SELECTED ANALYTICAL APPLICATIONS OF LASER PLASMAS AND LASER-ABLATION, 1987-1994 [J].
RADZIEMSKI, LJ .
MICROCHEMICAL JOURNAL, 1994, 50 (03) :218-234
[5]  
Schechter I, 1997, REV ANAL CHEM, V16, P173
[6]   Inductively coupled argon plasma continuous emissions monitor for hazardous air pollutant metals [J].
Seltzer, MD ;
Meyer, GA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (09) :2665-2672
[7]   Applications of laser-induced breakdown spectrometry [J].
Song, K ;
Lee, YI ;
Sneddon, J .
APPLIED SPECTROSCOPY REVIEWS, 1997, 32 (03) :183-235
[8]   Influence of ambient conditions on the laser air spark [J].
Yalçin, S ;
Crosley, DR ;
Smith, GP ;
Faris, GW .
APPLIED PHYSICS B-LASERS AND OPTICS, 1999, 68 (01) :121-130
[9]   Laser-induced breakdown spectrometry as a multimetal continuous-emission monitor [J].
Zhang, HS ;
Yueh, FY ;
Singh, JP .
APPLIED OPTICS, 1999, 38 (09) :1459-1466