Comparison of three instruments for measuring red blood cell aggregation

被引:51
作者
Baskurt, Oguz K. [1 ]
Uyuklu, Mehmet [1 ]
Ulker, Pinar [1 ]
Cengiz, Melike [1 ]
Nemeth, Norbert [2 ]
Alexy, Tamas [3 ]
Shin, Sehyun [4 ]
Hardeman, Max R. [5 ]
Meiselman, Herbert J. [3 ]
机构
[1] Akdeniz Univ, Dept Physiol, Fac Med, TR-07058 Antalya, Turkey
[2] Univ Debrecen, Dept Operat Tech & Surg Res, Inst Surg, Med & Hlth Sci Ctr, Debrecen, Hungary
[3] Univ So Calif, Keck Sch Med, Dept Physiol & Biophys, Los Angeles, CA 90033 USA
[4] Korea Univ, Dept Mech Engn, Seoul, South Korea
[5] Univ Amsterdam, Acad Med Ctr, Dept Physiol, NL-1105 AZ Amsterdam, Netherlands
关键词
Erythrocyte aggregation; light transmittance; light reflectance; intrumentation; standardized difference; ERYTHROCYTE AGGREGATION; RHEOLOGICAL PROPERTIES; STIRRING-SYSTEM; AGGREGOMETER;
D O I
10.3233/CH-2009-1240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The International Society for Clinical Hemorheology organized a workshop to compare three instruments for measuring RBC aggregation: LORCA, Myrenne Aggregometer and RheoScan-A. The Myrenne Aggregometer provides indices at stasis (M) and at low shear (M1), with four indices obtained with the LORCA and RheoScan-A: amplitude (AMP), half-time (T-1/2), surface area (SA) above (LORCA) or below (RheoScan-A) the syllectogram, and the ratio (AI) of the area above (LORCA) or below (RheoScan-A) the syllectogram to total area (AI). Intra-assay reproducibility and biological variability were determined; also studied were RBC in diluted plasma and in 1% 500 kDa dextran, and 0.003% glutaradehyde (GA)-treated cells in plasma. All measurements were performed at 37 degrees C. Standardized difference values were used as a measure of power to detect differences. Salient results were: (1) intra-assay variations below 5% except for RheoScan-A AMP and SA; (2) biological variability greatest for T-1/2 with other indices similar for the three devices; (3) all instruments detected progressive changes with plasma dilution; (4) the Myrenne and LORCA, but not the RheoScan-A, detected differences for cells in dextran; (5) GA-treatment significantly affected the LORCA (AMP, T-1/2, SA, AI), the RheoScan-A (AMP, SA, AI) and the Myrenne M parameter. It is concluded that: (a) the LORCA, Myrenne and the RheoScan-A have acceptable precision and suitable power for detecting reduced aggregation due to plasma dilution; (b) greatly enhanced RBC aggregation may not be sensed by the RheoScan-A while the Myrenne M1 index may be insensitive to minor increases of cell rigidity; (c) future studies should define each instrument's useful range for detecting RBC aggregation.
引用
收藏
页码:283 / 298
页数:16
相关论文
共 32 条
[1]   The hydrodynamic radii of macromolecules and their effect on red blood cell aggregation [J].
Armstrong, JK ;
Wenby, RB ;
Meiselman, HJ ;
Fisher, TC .
BIOPHYSICAL JOURNAL, 2004, 87 (06) :4259-4270
[2]  
Baskurt OK, 2007, BIOMED HEALTH RES, V69, P170
[3]   In vivo correlates of altered blood rheology [J].
Baskurt, Oguz K. .
BIORHEOLOGY, 2008, 45 (06) :629-638
[4]  
Baskurt OK, 1996, CLIN HEMORHEOL, V16, P753
[5]  
Baskurt OK, 1998, CLIN HEMORHEOL MICRO, V19, P307
[6]  
Baskurt OK, 2003, SEMIN THROMB HEMOST, V29, P435
[7]  
BAUERSACHS RM, 1989, CLIN HEMORHEOL, V9, P1
[8]  
Chien S., 1975, The red blood cell - a comprehensive treatise, V2, P1031
[9]   Red blood cell rheology in patients with chronic venous disease (CVD) [J].
Chwala, Maciej ;
Spannbauer, Anna ;
Teleglow, Aneta ;
Cencora, Andrzej ;
Marchewka, Anna ;
Hardeman, Max R. ;
Dabrowski, Zbigniew .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 41 (03) :189-195
[10]  
Cohen J., 1988, Statistical power analysis for the behavioural sciences, V2nd