Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation

被引:159
作者
Aoki, Jiro
Nakazawa, Gaku
Tanabe, Kengo
Hoye, Angela
Yamamoto, Hirosada
Nakayama, Tomohiro
Onuma, Yoshinobu
Higashikuni, Yasutomi
Otsuki, Syuji
Yagishita, Atsuhiko
Yachi, Sen
Nakajima, Hiroyoshi
Hara, Kazuhiro
机构
[1] Mitsui Mem Hosp, Div Cardiol, Tokyo 101, Japan
[2] Castle Hill Hosp, Dept Cardiol, Kingston Upon Hull, Yorks, England
关键词
stent; fracture; restenosis;
D O I
10.1002/ccd.20950
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stent fracture is one of the possible causes of restenosis after sirolimus-eluting stents (SES) implantation. The aim of our study was to evaluate the prevalence and clinical impact of coronary stent fracture after SES implantation. Methods: From our prospective institutional database, 280 patients were treated solely with SES from August 2004 to June 2005. Among the 280 patients, 256 patients with a total of 307 lesions underwent follow-up angiography on an average of 240 days after the procedure. Results: Stent fractures were observed in eight (2.6%) lesions. Of the eight lesions with stent fracture, five were located in the right coronary artery (RCA), two in the saphenous vein (SV) graft, and one in the left anterior descending coronary artery. The stent fractures were all in the locations that served as hinges during vessel movement in the cardiac contraction cycle. Seven of the eight stent fractures were adjacent to the edge of previously implanted or overlapped stent. Significant multivariate predictors of stent fracture were SV graft location (Odds ratio 35.88; 95% confidence interval 2.73-471.6, P = 0.006), implanted stent length (Odds ratio 1.04; 95% confidence interval 1.01-1.07, P = 0.02), and RCA location (Odds ratio 10.00; 95% confidence interval 1.11-89.67, P = 0.04). In-stent binary restenosis rate was 37.5% and target lesion repeat revascularization rate was 50.0% in patients with stent fracture. Conclusions: Stent fracture was likely to be affected by mechanical stress provoked by rigid structures and hinge points. Stent fracture might be associated with the high incidence of target lesion revascularization. (C) 2006 Wiley-Liss, Inc.
引用
收藏
页码:380 / 386
页数:7
相关论文
共 17 条
[1]  
Brilakis Emmanouil S, 2004, J Invasive Cardiol, V16, P545
[2]   Coronary-stent fracture [J].
Chowdhury, PS ;
Ramos, RG .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (08) :581-581
[3]   Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation [J].
Colombo, A ;
Orlic, D ;
Stankovic, G ;
Corvaja, N ;
Spanos, V ;
Montorfano, M ;
Liistro, F ;
Carlino, M ;
Airoldi, F ;
Chieffo, A ;
Di Mario, C .
CIRCULATION, 2003, 107 (17) :2178-2180
[4]   Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease [J].
Duda, SH ;
Pusich, B ;
Richter, G ;
Landwehr, P ;
Oliva, VL ;
Tielbeek, A ;
Wiesinger, B ;
Hak, JB ;
Tielemans, H ;
Ziemer, G ;
Cristea, E ;
Lansky, A ;
Bérégi, JP .
CIRCULATION, 2002, 106 (12) :1505-1509
[5]   Clinical assessment of a new real time 3D quantitative coronary angiography system: Evaluation in stented vessel segments [J].
Gradaus, R ;
Mathies, K ;
Breithardt, G ;
Boecker, D .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) :44-49
[6]   Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis [J].
Halkin, A ;
Carlier, S ;
Leon, MB .
HEART, 2004, 90 (08) :e45
[7]  
Hamilos Michalis I, 2005, Hellenic J Cardiol, V46, P439
[8]   Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis [J].
Han, RO ;
Schwartz, RS ;
Kobayashi, Y ;
Wilson, SH ;
Mann, JT ;
Sketch, MH ;
Safian, RD ;
Lansky, A ;
Popma, J ;
Fitzgerald, PJ ;
Palacios, IF ;
Chazin-Caldie, M ;
Goldberg, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03) :253-259
[9]   Coronary restenosis after sirolimus-eluting stent implantation - Morphological description and mechanistic analysis from a consecutive series of cases [J].
Lemos, PA ;
Saia, F ;
Ligthart, JMR ;
Arampatzis, CA ;
Sianos, G ;
Tanabe, K ;
Hoye, A ;
Degertekin, M ;
Daemen, J ;
McFadden, E ;
Hofma, S ;
Smits, PC ;
de Feyter, P ;
van der Giessen, WJ ;
van Domburg, RT ;
Serruys, PW .
CIRCULATION, 2003, 108 (03) :257-260
[10]   Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the "real world" -: The Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) Registry [J].
Lemos, PA ;
Serruys, PW ;
van Domburg, RT ;
Saia, F ;
Arampatzis, CA ;
Hoye, A ;
Degertekin, M ;
Tanabe, K ;
Daemen, J ;
Liu, TKK ;
McFadden, E ;
Sianos, G ;
Hofma, SH ;
Smits, PC ;
van der Giessen, WJ ;
de Feyter, PJ .
CIRCULATION, 2004, 109 (02) :190-195