Performance of a monolithic silica column in a capillary under pressure-driven and electrodriven conditions

被引:290
作者
Ishizuka, N
Minakuchi, H
Nakanishi, K
Soga, N
Nagayama, H
Hosoya, K
Tanaka, N [1 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Dept Chem Mat, Sakyo Ku, Kyoto 6068501, Japan
[2] Kyoto Inst Technol, Dept Polymer Sci & Engn, Sakyo Ku, Kyoto 6068585, Japan
关键词
D O I
10.1021/ac990942q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous macroporous silica gel network was prepared in a fused-silica capillary and evaluated in reserved-phase liquid chromatography. Under pressure-driven conditions, the monolithic silica column derivatized to C-18 phase (100 mu m in diameter, 25 cm in length, silica skeleton size of similar to 2.2 mu m) produced plate heights of about 23 and 81 mu m at 0.5 mm/s with a pressure drop of 0.4, kg/cm(2), and at 0.5 mm/s with 3.6 kg/cm(2), respectively, in 90% acetonitrile for hexylbenzene with a k value of 0.7. The separation impedance, E, calculated for the present monolithic silica column was much smaller at a low how rate than those for particle-packed columns, although higher E values were obtained at a higher now rate. Considerable dependence of column efficiency on the linear velocity of the mobile phase was observed despite the small size of the silica skeletons. A major source of band broadening in the HPLC mode was found in the A term of the van Deemter equation. The performance of the continuous silica capillary column in the electrodriven mode was much better than that in the pressure-driven mode. Plate heights of 7-8 mu m were obtained for alkylbenzenes at 0.7-1.3 mm/s, although the electroosmotic now was slow. In HPLC and CEC mode, the dependency of plate height k values of the solutes was observed as seen in open tube chromatography presumably due to the contribution of the large through-pores. Since monolithic silica capillary columns can provide high permeability, the pressure-driven operation at a very low pressure can afford a separation speed similar to CEC at a high electric field.
引用
收藏
页码:1275 / 1280
页数:6
相关论文
共 33 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[3]  
CHING QC, 1993, ANAL CHEM, V65, P2243
[4]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[5]   Preparation and characterization of monolithic porous capillary columns loaded with chromatographic particles [J].
Dulay, MT ;
Kulkarni, RP ;
Zare, RN .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5103-5107
[6]   Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds [J].
Ericson, C ;
Liao, JL ;
Nakazato, K ;
Hjerten, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :33-41
[7]   Silica xerogel as a continuous column support for high-performance liquid chromatography [J].
Fields, SM .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2709-2712
[8]   CAPILLARY ELECTROCHROMATOGRAPHY OF SMALL MOLECULES IN POLYACRYLAMIDE GELS WITH ELECTROOSMOTIC FLOW [J].
FUJIMOTO, C ;
KINO, J ;
SAWADA, H .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :107-113
[9]   Fabrication of nanocolumns for liquid chromatography [J].
He, B ;
Tait, N ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3790-3797
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS ON COMPRESSED, NON-POROUS AGAROSE BEADS .1. HYDROPHOBIC-INTERACTION CHROMATOGRAPHY [J].
HJERTEN, S ;
LIAO, JL .
JOURNAL OF CHROMATOGRAPHY, 1988, 457 :165-174