Comparison of single-biphasic versus sequential-biphasic shocks on defibrillation threshold in pigs

被引:5
作者
Csanadi, Z
Jones, DL
Wood, GK
Klein, GJ
机构
[1] UNIV WESTERN ONTARIO,DEPT PHYSIOL,LONDON,ON,CANADA
[2] UNIV WESTERN ONTARIO,DEPT MED,LONDON,ON,CANADA
[3] JOHN P ROBARTS RES INST,HEART & CIRCULAT GRP,LONDON,ON N6A 5K8,CANADA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 06期
关键词
implantable defibrillators; defibrillation threshold; sequential-biphasic shock;
D O I
10.1111/j.1540-8159.1997.tb03528.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current generation implantable cardioverter defibrillators use monophasic, biphasic, or sequential pulse shocks, most of which truncate after a given time, dumping the remaining charge on the capacitor through an infernal resistor. We hypothesized that having an additional current pathway, and delivering the majority of the remaining charge on a single capacitor to the two pathways using additional shock phases, would improve defibrillation efficacy. This hypothesis was tested by comparing DFTs using a simulated single capacitor, single-biphasic shock (two 5-ms pulses separated by 0.2 ms), delivered to coupled pairs of electrodes, to those using a sequential-biphasic shock (four 5-ms pulses separated by 0.2 ms) delivered to separate opposing electrodes, delivered from the same electrodes for both waveforms. In eight open-chest anesthetized pigs, four mesh electrodes (Medtronic TX-7, 6.5 cm(2)), were sutured on the epicardium of the anterior and posterior surfaces of each ventricle. Shocks were delivered from a 200-mu F capacitor bank. Triplicate DFTs were obtained using each waveform in a randomized crossover design. Initial leading edge voltage (mean +/- SEM: 420 +/- 33 V vs 497 +/- 34 V; P < 0.05), initial peak current (4.8 +/- 0.4 A vs 13 +/- 1.1 A; P < 0.001), and delivered energy (16.9 +/- 2.6 J vs 30.4 +/- 5.3 J; P < 0.05) at the DFT were all significantly lower using sequential-biphasic shocks than those using single-biphasic shocks, respectively. We conclude that for direct heart defibrillation, it is worthwhile to combine sequential capability to biphasic shocks and deliver the remaining charge on the capacitor to the two different pathways.
引用
收藏
页码:1606 / 1612
页数:7
相关论文
共 31 条
[1]   ELECTRODE SYSTEM INFLUENCE ON BIPHASIC WAVE-FORM DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
TROUTMAN, C ;
JOHNSON, G ;
MEHRA, R ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
GARTMAN, DM .
CIRCULATION, 1991, 84 (02) :665-671
[2]  
BOURLAND JD, 1986, MED INSTRUM, V20, P138
[3]  
BOURLAND JD, 1978, MED INSTRUM, V12, P38
[4]   COMPARISON OF MONOPHASIC WITH SINGLE AND DUAL CAPACITOR BIPHASIC WAVEFORMS FOR NONTHORACOTOMY CANINE INTERNAL DEFIBRILLATION [J].
CHAPMAN, PD ;
VETTER, JW ;
SOUZA, JJ ;
WETHERBEE, JN ;
TROUP, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (01) :242-245
[5]  
COOPER R A S, 1992, Journal of the American College of Cardiology, V19, p162A
[6]  
COOPER RAS, 1983, PACE, V16, P471
[7]   IMPROVED DEFIBRILLATION THRESHOLDS WITH LARGE CONTOURED EPICARDIAL ELECTRODES AND BIPHASIC WAVE-FORMS [J].
DIXON, EG ;
TANG, ASL ;
WOLF, PD ;
MEADOR, JT ;
FINE, MJ ;
CALFEE, RV ;
IDEKER, RE .
CIRCULATION, 1987, 76 (05) :1176-1184
[8]   COMBINATION BIPHASIC WAVE-FORM PLUS SEQUENTIAL PULSE DEFIBRILLATION IMPROVES DEFIBRILLATION EFFICACY OF A NONTHORACOTOMY LEAD SYSTEM [J].
EXNER, D ;
YEE, R ;
JONES, DL ;
KLEIN, GJ ;
MEHRA, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :317-322
[9]   STRENGTH DURATION AND PROBABILITY OF SUCCESS CURVES FOR DEFIBRILLATION WITH BIPHASIC WAVE-FORMS [J].
FEESER, SA ;
TANG, ASL ;
KAVANAGH, KM ;
ROLLINS, DL ;
SMITH, WM ;
WOLF, PD ;
IDEKER, RE .
CIRCULATION, 1990, 82 (06) :2128-2141
[10]   THE DEFIBRILLATION THRESHOLD - HOW MANY MEASUREMENTS ARE ENOUGH [J].
FUJIMURA, O ;
JONES, DL ;
KLEIN, GJ .
AMERICAN HEART JOURNAL, 1989, 117 (04) :977-979