Performance optimization in elastography: Multicompression with temporal stretching

被引:64
作者
Varghese, T
Ophir, J
机构
[1] Ultrasonics Laboratory, Medical School, University of Texas, Houston
关键词
dynamic range; elastography; multicompression; strain filter; temporal stretching; ultrasound;
D O I
10.1006/uimg.1996.0011
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A general theoretical framework known as the strain filter has been previously used to evaluate the performance in elastography. The strain filter describes the relationship among the resolution, dynamic range, sensitivity and elastographic SNR (SNR(e)), and may be plotted as a graph of the upper bound of the SNR(e) vs. the strain experienced by the tissue, for a desired elastographic axial resolution as determined by the data window length. The ideal strain filter has an infinitely high, flat all-pass characteristic shape in the strain domain, which means that all local tissue strains are displayed in the elastogram with infinite SNR(e); it also means that the strain dynamic range in the elastogram is infinite as well. Practical strain filters obtained using a single tissue compression have a bandpass characteristic shape in the strain domain, where the -3 dB width of this bandpass characteristic may be defined as the elastographic dynamic range. In this paper, we present an optimal technique for stretching multicompression elastography, practiced by selecting the optimum incremental applied strain using the strain filter. Two techniques, temporal stretching and multicompression elastography, are combined in this paper to improve elastogram quality. Stretching multicompression elastography using the optimal applied strain increment alters the shape of the strain filter from its bandpass characteristic to a more desirable high-emphasis filter. The dynamic range of optimal stretching multicompression elastography is limited only by tissue nonlinearities. This optimal applied strain increment minimizes signal decorrelation and achieves the maximum achievable elastographic SNR(e).
引用
收藏
页码:193 / 214
页数:22
相关论文
共 29 条
[1]  
Bendat J., 2010, Random data: analysis and measurement procedures
[2]  
Cespedes E. I., 1993, ELASTOGRAPHY IMAGING
[3]  
CESPEDES EI, 1997, IEEE T ULTRASON FERR, V44
[4]   METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS [J].
CESPEDES, I ;
HUANG, Y ;
OPHIR, J ;
SPRATT, S .
ULTRASONIC IMAGING, 1995, 17 (02) :142-171
[5]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[6]   REDUCTION OF IMAGE NOISE IN ELASTOGRAPHY [J].
CESPEDES, I ;
OPHIR, J .
ULTRASONIC IMAGING, 1993, 15 (02) :89-102
[7]   THEORETICAL BOUNDS ON STRAIN ESTIMATION IN ELASTOGRAPHY [J].
CESPEDES, I ;
INSANA, M ;
OPHIR, J .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (05) :969-972
[8]  
CULIOLI JL, 1992, P 38 INT C MEAT SCI, P135
[9]  
FRIEMEL BH, 1994, THESIS DUKE U
[10]  
HUANG Y, 1995, 39 ANN AIUM CONV SAN