Modulation of corticospinal excitability by paired associative stimulation: Reproducibility of effects and intraindividual reliability

被引:91
作者
Fratello, Fabiana
Veniero, Domenica
Curcio, Giuseppe
Ferrara, Michele
Marzano, Cristina
Moroni, Fabio
Pellicciari, Maria Concetta
Bertini, Mario
Rossini, Paolo Maria
De Gennaro, Luigi
机构
[1] Univ Roma La Sapienza, Dept Psychol, Rome, Italy
[2] Univ Brescia, Dept Biomed Sci & Biotechnol, I-25121 Brescia, Italy
[3] Univ Aquila, Dept Internal Med & Publ Hlth, I-67100 Laquila, Italy
[4] IRCCS, Ctr S Giovanni di Dio FBF, Brescia, Italy
[5] Hosp Fatebenfratelli, Dept Neurosci, AFaR, Rome, Italy
[6] Dept Neurol, Rome, Italy
[7] Univ Europea Roma, Rome, Italy
关键词
PAS; TMS; reproducibility; reliability; cortical plasticity; peripheral stimulation;
D O I
10.1016/j.clinph.2006.07.315
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Electrical stimulation of the median nerve followed by a magnetic pulse on the primary motor cortex (M1) is effective to cause an increase in the amplitude of motor evoked potential (MEP) registered in the target muscle with the interstimulus interval (ISI) at 25 ms (paired associative stimulation, PAS). The aim of this study is to evaluate the reproducibility of PAS with ISI 25 (PAS25), assessed in two separate sessions. Intraindividual reliability of TMS measures was also evaluated. Methods: Motor threshold of abductor pollicis brevis (APB), assessed at rest, and MEP amplitude of APB and abductor digiti minimi (ADM) were assessed before and after PAS25 in 18 healthy volunteers (nine males and nine females). Results: Data showed a significant increase of MEP amplitude in the target muscle (APB) after PAS25 and a reproducibility of group effect in the two sessions, as assessed by ANOVA, but a lack of intraindividual reliability, as assessed by intraclass correlation coefficients (ICC). Conclusions: The results underline the reproducibility of mean effects and the need to be careful when comparing the same subject on different days. Significance: Electrical stimulation of the median nerve followed by a magnetic pulse delivered on M1 after 25 ms causes a reproducible increase in MEP amplitude, without showing an acceptable intraindividual reliability. (c) 2006 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2667 / 2674
页数:8
相关论文
共 47 条
[1]  
[Anonymous], ELECTROENCEPHALOGR C
[2]  
BAGNATO S, 2005, MOV DISORD
[3]  
Boroojerdi B, 2000, MUSCLE NERVE, V23, P1594, DOI 10.1002/1097-4598(200010)23:10<1594::AID-MUS19>3.0.CO
[4]  
2-3
[5]   Reliability of the input-output properties of the cortico-spinal pathway obtained from transcranial magnetic and electrical stimulation [J].
Carroll, TJ ;
Riek, S ;
Carson, RG .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 112 (02) :193-202
[6]   Prolonged peripheral nerve stimulation induces persistent changes in excitability of human motor cortex [J].
Charlton, CS ;
Ridding, MC ;
Thompson, PD ;
Miles, TS .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2003, 208 (1-2) :79-85
[7]  
Classen Joseph, 2004, Suppl Clin Neurophysiol, V57, P563
[8]   Intra- and intersubject reliability of abductor pollicis brevis muscle motor map characteristics with transcranial magnetic stimulation [J].
Corneal, SF ;
Butler, AJ ;
Wolf, SL .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (08) :1670-1675
[9]   Reproducibility of callosal effects of transcranial magnetic stimulation (TMS) with interhemispheric paired pulses [J].
De Gennaro, L ;
Ferrara, M ;
Bertini, M ;
Pauri, F ;
Cristiani, R ;
Curcio, G ;
Romei, V ;
Fratello, F ;
Rossini, PM .
NEUROSCIENCE RESEARCH, 2003, 46 (02) :219-227
[10]  
DEUSCHL G, 1991, EXP BRAIN RES, V83, P403