Reliability of echocardiographic assessment of left ventricular structure and function -: The PRESERVE study

被引:272
作者
Palmieri, V
Dahlöf, B
DeQuattro, V
Sharpe, N
Bella, JN
de Simone, G
Paranicas, M
Fishman, D
Devereux, RB
机构
[1] Cornell Univ, Weill Med Coll, New York Presbyterian Hosp, Div Cardiol, New York, NY 10021 USA
[2] Univ Gothenburg, Gothenburg, Sweden
[3] Univ So Calif, Los Angeles Cty Med Ctr, White Mem Med Ctr, Los Angeles, CA 90033 USA
[4] Auckland Hosp, Dept Med, Auckland, New Zealand
关键词
D O I
10.1016/S0735-1097(99)00396-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The study was done to evaluate reliability of echocardiographic left ventricular (LV) mass. BACKGROUND Echocardiographic estimation of LV mass is affected by several sources of variability. METHODS We assessed intrapatient reliability of LV mass measurements in 183 hypertensive patients (68% men, 65 +/- 9 years) enrolled in the Prospective Randomized Enalapril Study Evaluating Regression of Ventricular Enlargement (PRESERVE) trial after a screening echocardiogram (ECHO) showed LV hypertrophy. A second ECHO was repeated at randomization (45 +/- 25 days later). Two-dimensional (2D)-guided M-mode or 2D linear measurements of LV cavity and wall dimensions were verified by one experienced reader. RESULTS Mean LV mass was similar at first and second ECHO (243 +/- 53 vs. 241 +/- 54 g) and showed high reliability as estimated by intraclass correlation coefficient (RHO) = 0.93. Within-patient 5th, 10th, 90th and 95th percentiles of between-study difference in LV mass were -32 g, -28 g, +25 g and +35 g. Mean LV mass fell less from the first to the second ECHO than expected from a formula to predict regression to the mean (2 +/- 19 vs. 17 +/- 12 g, p < 0.001). Reliability was also high for LV internal diameter (RHO = 0.87), septal (RHO = 0.85) and posterior wall thickness (RHO = 0.83). Substantial or moderate reliability was observed for measures of LV systolic function and diastolic filling (RHO from 0.71 to 0.57). CONCLUSIONS Left Ventricular mass had high reliability and little regression to the mean; between-study LV mass change of +/-35 g or +/-17 g had greater than or equal to 95% or greater than or equal to 80% likelihood of being true change. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:1625 / 1632
页数:8
相关论文
共 33 条
[1]   LEFT-VENTRICULAR MASS AND RISK OF STROKE IN AN ELDERLY COHORT - THE FRAMINGHAM HEART-STUDY [J].
BIKKINA, M ;
LEVY, D ;
EVANS, JC ;
LARSON, MG ;
BENJAMIN, EJ ;
WOLF, PA ;
CASTELLI, WP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (01) :33-36
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
COLLINS HW, 1989, J AM COLL CARDIOL, V14, P672
[4]  
DAHLOF B, 1999, J AM COLL CARDIOL, V23, pA227
[5]   EFFECT OF REGRESSION TO MEAN IN EPIDEMIOLOGIC AND CLINICAL STUDIES [J].
DAVIS, CE .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1976, 104 (05) :493-498
[6]  
DESIMONE G, 1994, J HYPERTENS, V12, P1129
[7]   ASSESSMENT OF LEFT-VENTRICULAR FUNCTION BY THE MIDWALL FRACTIONAL SHORTENING END-SYSTOLIC STRESS RELATION IN HUMAN HYPERTENSION [J].
DESIMONE, G ;
DEVEREUX, RB ;
ROMAN, MJ ;
GANAU, A ;
SABA, PS ;
ALDERMAN, MH ;
LARAGH, JH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) :1444-1451
[8]   Regression of left ventricular hypertrophy as a surrogate end-point for morbid events in hypertension treatment trials [J].
Devereux, RB ;
AgabitiRosei, E ;
Dahlof, B ;
Gosse, P ;
Hahn, RT ;
Okin, PM ;
Roman, MJ .
JOURNAL OF HYPERTENSION, 1996, 14 :S95-S101
[9]   ROLE OF PRECLINICAL CARDIOVASCULAR-DISEASE IN THE EVOLUTION FROM RISK FACTOR EXPOSURE TO DEVELOPMENT OF MORBID EVENTS [J].
DEVEREUX, RB ;
ALDERMAN, MH .
CIRCULATION, 1993, 88 (04) :1444-1455
[10]  
DEVEREUX RB, 1994, J HUM HYPERTENS, V8, P735