PM2.5 speciation trends network:: Evaluation of whole-system uncertainties using data from sites with collocated samplers

被引:48
作者
Flanagan, JB [1 ]
Jayanty, RKM [1 ]
Rickman, EE [1 ]
Peterson, MR [1 ]
机构
[1] RTI Int, Res Triangle Pk, NC 27709 USA
关键词
D O I
10.1080/10473289.2006.10464516
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objectives of this paper are to contrast the relative variability of replicate laboratory measurements of selected chemical components of fine particulate matter (PM) with total variability from collocated measurements and to compare the magnitudes of the uncertainties determined from collocated sampler data with those currently being provided to U.S. Environmental Protection Agency (EPA)'s Air Quality System (AQS) database by RTI International (RTI). Pointwise uncertainty values are needed for modeling and data analysis and should include all the random errors affecting each data point. Total uncertainty can be decomposed into two primary components: analytical measurement uncertainty and sampling uncertainty. Analytical measurement uncertainties are relatively easy to calculate from routine quality control (QC) data. Sampling uncertainties, on the other hand, are comparatively difficult to measure. In this paper, the authors describe data from collocated samplers to provide a snapshot of whole-system uncertainty for several important chemical species. The components of uncertainty were evaluated for key species from each of the analytical methods employed by the PM2.5 Speciation Trends Network (STN) program: gravimetry, ion chrornatography (IC), X-ray fluorescence (XRF), and thermal-optical analysis for organic carbon and elemental carbon. The results show that the laboratory measurement uncertainties are typically very small compared with uncertainties calculated from the differences between samples collected from collocated samplers. These differences are attributable to the "field" components uncertainty, which may include contamination and/or losses during shipping, handling, and sampling, as well as other distortions of the concentration level due to flow and sample volume variations. Uncertainties calculated from the collocation results were found to be generally similar to the uncertainties currently being loaded into EPA's AQS system, with some exceptions described below.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2003, STANDARD OPERATING P
[2]  
[Anonymous], 1995, Guide to the expression of uncertainty in measurement (GUM)
[3]  
[Anonymous], THERMAL OPTICAL TRAN
[4]  
FLANAGAN JB, 2002, S AIR QUAL MEAS METH
[5]  
FLANAGAN JB, 2003, ESTIMATING ANAL MEAS
[6]  
FLANAGAN JB, 2004, S AIR QUAL MEAS METH
[7]  
Jayanty R., 2004, 13 WORLD CLEAN AIR C
[8]  
*NIOSH, 1997, NIOSH MAN AN METH
[9]  
*NRC COMM RES PRIO, 1998, RES PRIOR AIRB PART
[10]   Discarding or downweighting high-noise variables in factor analytic models [J].
Paatero, P ;
Hopke, PK .
ANALYTICA CHIMICA ACTA, 2003, 490 (1-2) :277-289