The value of compressed air energy storage with wind in transmission-constrained electric power systems

被引:228
作者
Denholm, Paul [1 ]
Sioshansi, Ramteen [2 ]
机构
[1] Natl Renewable Energy Lab, Golden, CO 80401 USA
[2] Ohio State Univ, Columbus, OH 43210 USA
关键词
Wind; Energy storage; Transmission; EMISSIONS; ECONOMICS;
D O I
10.1016/j.enpol.2009.04.002
中图分类号
F [经济];
学科分类号
02 ;
摘要
In this work, we examine the potential advantages of co-locating wind and energy storage to increase transmission utilization and decrease transmission costs. Co-location of wind and storage decreases transmission requirements, but also decreases the economic value of energy storage compared to locating energy storage at the load. This represents a tradeoff which we examine to estimate the transmission costs required to justify moving storage from load-sited to wind-sited in three different locations in the United States. We examined compressed air energy storage (CAES) in three "wind by wire" scenarios with a variety of transmission and CAES sizes relative to a given amount of wind. In the sites and years evaluated, the optimal amount of transmission ranges from 60% to 100% of the wind farm rating, with the optimal amount of CAES equal to 0-35% of the wind farm rating, depending heavily on wind resource, value of electricity in the local market, and the cost of natural gas. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3149 / 3158
页数:10
相关论文
共 26 条
[1]  
[Anonymous], EPRI DOE HDB EN STOR
[2]  
[Anonymous], 2008, BOTTL EL STOR STRAT
[3]  
[Anonymous], 7 INT WORKSH LARG SC
[4]  
[Anonymous], 2003, STUD EL TRANSM CONJ
[5]  
[Anonymous], E WIND INT TRANSM ST
[6]   HIGH-CAPACITY FACTOR WIND ENERGY-SYSTEMS [J].
CAVALLO, AJ .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (02) :137-143
[7]   The economics of large-scale wind power in a carbon constrained world [J].
DeCarolis, JF ;
Keith, DW .
ENERGY POLICY, 2006, 34 (04) :395-410
[8]   Improving the technical, environmental and social performance of wind energy systems using biomass-based energy storage [J].
Denholm, P .
RENEWABLE ENERGY, 2006, 31 (09) :1355-1370
[9]   Emissions and energy efficiency assessment of baseload wind energy systems [J].
Denholm, P ;
Kulcinski, GL ;
Holloway, T .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (06) :1903-1911
[10]   Life cycle energy requirements and greenhouse gas emissions from large scale energy storage systems [J].
Denholm, P ;
Kulcinski, GL .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) :2153-2172