Use of a decibel threshold in detecting Doppler embolic signals

被引:36
作者
Markus, HS [1 ]
Molloy, J [1 ]
机构
[1] UNIV LONDON KINGS COLL,SCH MED & DENT,DEPT NEUROL,LONDON,ENGLAND
关键词
carotid stenosis; cerebral embolism; ultrasonics;
D O I
10.1161/01.STR.28.4.692
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose To improve reproducibility and reliability in the identification of embolic signals detected with the use of Doppler ultrasound, many studies have used an intensity threshold. However, variable thresholds between 3 and 12 dB have been used, and often the method of measurement of intensity is not stated. Potentially different methods of measurement could result in different intensity measurements for the same embolic signal. We determined the effect of these differences using commercial transcranial Doppler systems. Methods We analyzed 81 embolic signals recorded from the middle cerebral arteries of patients with carotid artery disease using three different methods of measuring intensity that had been previously used in research studies. In method 1 individual lime frames of the frequency spectra were analyzed, in method 2 a color-coded intensity scale was used, and in method 3 automated software was used. Results There was a highly significant correlation between measurements made by the different techniques (method 1 versus method 2: r = .68, P < .0001; method 1 versus method 3: r = .66, P < .0001; method 2 versus method 3: r = .70: P < .0001). However, the absolute values of intensity for the same embolic signals varied markedly for the different methods. For example, a 4-dB threshold according to method 1 was equivalent to an approximately 7-dB threshold measured by method 2. These differences had major effects on the proportion of embolic signals detected with the use of the same decibel threshold but with intensity measured in the different ways. For example, using a threshold of 7 dB would result in only 4.9% of signals being missed by method 2 but 42.2% and 51.4% being missed by methods 1 and 3, respectively. Conclusions Our results demonstrate that the intensities of the same embolic signals, recorded with the same parameters, are markedly different when analyzed in the different ways used in previous studies. This has important implications when a decibel threshold is used and emphasizes that criteria developed by one investigator on one machine cannot be used by another investigator without initial reevaluation. This could account for some of the differences in frequencies of embolic signals reported in previous clinical studies.
引用
收藏
页码:692 / 695
页数:4
相关论文
共 24 条
[1]   CLINICAL CORRELATES OF HIGH-INTENSITY TRANSIENT SIGNALS DETECTED ON TRANSCRANIAL DOPPLER SONOGRAPHY IN PATIENTS WITH CEREBROVASCULAR-DISEASE [J].
BABIKIAN, VL ;
HYDE, C ;
POCHAY, V ;
WINTER, MR .
STROKE, 1994, 25 (08) :1570-1573
[2]  
BRAEKKEN SK, 1995, STROKE, V26, P1225
[3]  
DEMARIN V, 1996, CEREBROVASC DIS S3, V6, P243
[4]   Variability in occurrence of embolic signals in long term transcranial Doppler recordings [J].
Droste, DW ;
Decker, W ;
Siemens, HJ ;
Kaps, M ;
SchulteAltedorneburg, G .
NEUROLOGICAL RESEARCH, 1996, 18 (01) :25-30
[5]   Cardiac microembolism: Prevalence and clinical outcome [J].
Eicke, BM ;
Barth, V ;
Kukowski, B ;
Werner, G ;
Paulus, W .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 1996, 136 (1-2) :143-147
[6]   Effect of time and cerebrovascular symptoms on the prevalence of microembolic signals in patients with cervical carotid stenosis [J].
Forteza, AM ;
Babikian, VL ;
Hyde, C ;
Winter, M ;
Pochay, V .
STROKE, 1996, 27 (04) :687-690
[7]   A novel technique for identification of Doppler microembolic signals based on the coincidence method - In vitro and in vivo evaluation [J].
Georgiadis, D ;
Goeke, J ;
Hill, M ;
Konig, M ;
Nabavi, DG ;
Stogbauer, F ;
Zunker, P ;
Ringelstein, EB .
STROKE, 1996, 27 (04) :683-686
[8]   DETECTION OF INTRACRANIAL EMBOLI IN PATIENTS WITH CAROTID DISEASE [J].
GEORGIADIS, D ;
GROSSET, DG ;
QUIN, RO ;
NICHOL, JAR ;
BONE, I ;
LEES, KR .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (03) :309-314
[9]   DOPPLER EMBOLI SIGNALS VARY ACCORDING TO STROKE SUBTYPE [J].
GROSSET, DG ;
GEORGIADIS, D ;
ABDULLAH, I ;
BONE, I ;
LEES, KR .
STROKE, 1994, 25 (02) :382-384
[10]   QUANTIFICATION OF ULTRASOUND EMBOLI SIGNALS IN PATIENTS WITH CARDIAC AND CAROTID DISEASE [J].
GROSSET, DG ;
GEORGIADIS, D ;
KELMAN, AW ;
LEES, KR .
STROKE, 1993, 24 (12) :1922-1924