Effective doses to patients undergoing thoracic computed tomography examinations

被引:115
作者
Huda, W [1 ]
Scalzetti, EM [1 ]
Roskopf, M [1 ]
机构
[1] SUNY Syracuse, Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
关键词
computed tomography; dosimetry; effective dose; technique factors; energy imparted;
D O I
10.1118/1.598949
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded fur 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age, All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r(2) = 0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:838 / 844
页数:7
相关论文
共 19 条
[1]  
Almen A., 1996, Journal of Radiological Protection, V16, P81, DOI 10.1088/0952-4746/16/2/004
[2]  
[Anonymous], 1993, SOURC EFF ION RAD
[3]   Energy imparted and effective doses in computed tomography [J].
Atherton, JV ;
Huda, W .
MEDICAL PHYSICS, 1996, 23 (05) :735-741
[4]   CT DOSES IN CYLINDRICAL PHANTOMS [J].
ATHERTON, JV ;
HUDA, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :891-911
[5]   Use of the concept of energy imparted in diagnostic radiology [J].
Carlsson, GA ;
Dance, DR ;
Persliden, J ;
Sandborg, M .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) :39-62
[6]   AN ATTEMPT TO STANDARDIZE THE RADIODIAGNOSTIC RISK STATEMENT IN AN INSTITUTIONAL REVIEW BOARD CONSENT FORM [J].
CASTRONOVO, FP .
INVESTIGATIVE RADIOLOGY, 1993, 28 (06) :533-538
[7]   DIAGNOSTIC THYROID PROCEDURES AND CORRESPONDING RADIATION-DOSES IN MANITOBA - 1981-1985 [J].
HUDA, W ;
GORDON, K ;
GREENBERG, ID .
HEALTH PHYSICS, 1990, 59 (03) :287-293
[8]   An approach for the estimation of effective radiation dose at CT in pediatric patients [J].
Huda, W ;
Atherton, JV ;
Ware, DE ;
Cumming, WA .
RADIOLOGY, 1997, 203 (02) :417-422
[9]  
*INT COMM RAD PROT, 1991, ANN ICRP 21
[10]  
*INT COMM RAD PROT, 1982, PUBL, V34