Contrast-agent phase effects: An experimental system for analysis of susceptibility, concentration, and bolus input function kinetics

被引:42
作者
Akbudak, E
Norberg, RE
Conturo, TE
机构
[1] WASHINGTON UNIV,SCH MED,DIV RADIOL SCI,NEUROIMAGING LAB,MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
[2] WASHINGTON UNIV,DEPT PHYS,ST LOUIS,MO 63130
关键词
MRI; susceptibility; contrast agents; perfusion;
D O I
10.1002/mrm.1910380619
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A system is presented for experimental arterial input function (AIF) simulation and for accurate measurement of the concentration, susceptibility effects, and magnetic moment of paramagnetic MR contrast agents. Signal effects of contrast agents are evaluated with a stable, well-characterized, and precise experimental setup. A cylindrical phantom and a closed-loop circulating flow system were designed for AIF simulation, assessment of the physical determinants of contrast-agent phase effects, and measurement of contrast-agent properties under controlled conditions, A mathematical model of the AIF dynamics is proposed. From the experimental phase shift (Delta phi), either the concentration or molar susceptibility, chi(M), is determined. The linear dependence of Delta phi on concentration and echo time (TE), the orientation dependence, and the lack of dependence on T-1, T-2, and diffusion time are proven precisely for water solutions under a wide variety of conditions, The measured effective magnetic moment of Gd+3, mu(eff), was 7.924 +/- 0.015 Bohr magnetons in agreement with the theoretical value of 7.937.
引用
收藏
页码:990 / 1002
页数:13
相关论文
共 29 条
[1]   Arterial input functions from MR phase imaging [J].
Akbudak, E ;
Conturo, TE .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :809-815
[2]  
AKBUDAK E, 1995, P SMR 3 ANN M NIC FR, P867
[3]  
AKBUDAK E, 1994, P SMR 2 ANN M SAN FR, P938
[4]  
[Anonymous], 1932, ELECT MAGNETIC SUSCE
[5]   SPECIFIC MEDIUM EFFECTS IN NUCLEAR MAGNETIC RESONANCE SPECTRA OF LIQUIDS [J].
BOTHNERBY, AA ;
GLICK, RE .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1956, 78 (05) :1071-1072
[6]  
CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
[7]   SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS [J].
CONTURO, TE ;
SMITH, GD .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :420-437
[8]   MR IMAGING OF CEREBRAL PERFUSION BY PHASE-ANGLE RECONSTRUCTION OF BOLUS PARAMAGNETIC-INDUCED FREQUENCY-SHIFTS [J].
CONTURO, TE ;
BARKER, PB ;
MATHEWS, VP ;
MONSEIN, LH ;
BRYAN, RN .
MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (02) :375-390
[9]  
CONTURO TE, 1993, J MAGN RESON IMAGING, V3, P62
[10]  
CONTURO TE, 1993, RADIOLOGY, V189, P184