Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining

被引:193
作者
Gupta, Rajiv [1 ]
Phan, Catherine M. [1 ]
Leidecker, Christianne [2 ]
Brady, Thomas J. [1 ]
Hirsch, Joshua A. [1 ]
Nogueira, Raul G. [1 ]
Yoo, Albert J. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Siemens Med Solut, Malvern, PA USA
关键词
CEREBRAL-ARTERY OCCLUSION; ACUTE ISCHEMIC-STROKE; INTRAARTERIAL THROMBOLYSIS; COMPUTED-TOMOGRAPHY; TRANSFORMATION; OUTCOMES; HEART;
D O I
10.1148/radiol.10091806
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the efficacy of dual-energy computed tomography (CT) in the differentiation of intracerebral hemorrhage (ICH) from iodinated contrast material in patients who received contrast material via intraarterial or intravenous delivery. Materials and Methods: This retrospective study was approved by the local institutional review board, which waived the informed consent requirement for the analysis. Sixteen patients with acute stroke and two with head trauma who had undergone intraarterial or intravenous administration of iodinated contrast material were evaluated by using dual-energy CT to differentiate areas of hyperattenuation secondary to contrast material staining from those representing ICH. A dual-energy CT scanner was used for imaging at 80 and 140 kV, and a three-material decomposition algorithm was used to obtain virtual unenhanced images and iodine overlay images. The sensitivity, specificity, and accuracy of dual-energy CT in the prospective differentiation of intraparenchymal contrast material from hemorrhage were obtained. Follow-up images were used as the standard of reference. Results: There were 28 intraparenchymal areas of hyperattenuation classified at dual-energy CT as iodinated contrast material staining (n = 20, 71%), hemorrhage (n = 5, 18%), or both (n = 3, 11 %). Two of the three areas of hyperattenuation seen on both virtual unenhanced and iodine overlay images were related to mineralization. The sensitivity, specificity, and accuracy of dual-energy CT in the identification of hemorrhage were 100% (six of six areas), 91% (20 of 22 areas), and 93% (26 of 28 areas), respectively. Conclusion: Dual-energy CT can help differentiate ICH from iodinated contrast material staining with high sensitivity and specificity in patients who have recently received intraarterial or intravenous iodinated contrast material. (C) RSNA, 2010
引用
收藏
页码:205 / 211
页数:7
相关论文
共 30 条
[1]   Guidelines for the early management of adults with ischemic stroke -: A guideline from the American Heart Association/American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the Atherosclerotic Peripheral Vascular Disease and Quality of Care Outcomes in Research Interdisciplinary Working Groups (Reprinted from Stroke, vol 38, pg 1655-1711, 2007) [J].
Adams, Harold P., Jr. ;
del Zoppo, Gregory ;
Alberts, Mark J. ;
Bhatt, Deepak L. ;
Brass, Lawrence ;
Furlan, Anthony ;
Grubb, Robert L. ;
Higashida, Randall T. ;
Jauch, Edward C. ;
Kidwell, Chelsea ;
Lyden, Patrick D. ;
Morgenstern, Lewis B. ;
Qureshi, Adnan I. ;
Rosenwasser, Robert H. ;
Scott, Phillip A. ;
Wijdicks, Eelco F. M. .
CIRCULATION, 2007, 115 (20) :E478-E534
[2]  
*AM SOC INT THER N, 2003, J VASC INTERV RADIOL, V14, P945
[3]   Hemorrhagic transformation of ischemic brain tissue -: Asymptomatic or symptomatic? [J].
Berger, C ;
Fiorelli, M ;
Steiner, T ;
Schäbitz, WR ;
Bozzao, L ;
Bluhmki, E ;
Hacke, W ;
von Kummer, R .
STROKE, 2001, 32 (06) :1330-1335
[5]   Intracerebral hemorrhage after intravenous t-PA therapy for ischemic stroke [J].
Brott, T ;
Broderick, J ;
Kothari, R ;
ODonoghue, M ;
Barsan, W ;
Tomsick, T ;
Spilker, J ;
Miller, R ;
Sauerbeck, L ;
Farrell, J ;
Kelly, J ;
Perkins, T ;
Miller, R ;
McDonald, T ;
Rorick, M ;
Hickey, C ;
Armitage, J ;
Perry, C ;
Thalinger, K ;
Rhude, R ;
Schill, J ;
Becker, PS ;
Heath, RS ;
Adams, D ;
Reed, R ;
Klei, M ;
Hughes, A ;
Anthony, J ;
Baudendistel, D ;
Zadicoff, C ;
Rymer, M ;
Bettinger, I ;
Laubinger, P ;
Schmerler, M ;
Meiros, G ;
Lyden, P ;
Dunford, J ;
Zivin, J ;
Rapp, K ;
Babcock, T ;
Daum, P ;
Persona, D ;
Brody, M ;
Jackson, C ;
Lewis, S ;
Liss, J ;
Mahdavi, Z ;
Rothrock, J ;
Tom, T ;
Zweifler, R .
STROKE, 1997, 28 (11) :2109-2118
[6]   Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[7]   Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[8]   The assessment of intracranial bleeding with virtual unenhanced imaging by means of dual-energy CT angiography [J].
Ferda, Jiri ;
Novak, Milan ;
Mirka, Hynek ;
Baxa, Jan ;
Ferdova, Eva ;
Bednarova, Alena ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Klotz, Ernst ;
Kreuzberg, Boris .
EUROPEAN RADIOLOGY, 2009, 19 (10) :2518-2522
[9]   Intra-arterial prourokinase for acute ischemic stroke - The PROACT II study: A randomized controlled trial [J].
Furlan, A ;
Higashida, R ;
Wechsler, L ;
Gent, M ;
Rowley, H ;
Kase, C ;
Pessin, M ;
Ahuja, A ;
Callahan, F ;
Clark, WM ;
Silver, F ;
Rivera, F .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (21) :2003-2011
[10]   Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440