Long-term ambulatory monitoring for cerebral emboli using transcranial Doppler ultrasound

被引:45
作者
Mackinnon, AD
Aaslid, R
Markus, HS
机构
[1] St George Hosp, Sch Med, Dept Clin Neurosci, London SW17 0RE, England
[2] Hemodynam AG, Bern, Switzerland
关键词
carotid stenosis; cerebral embolism; stroke; ultrasonography; Doppler; transcranial;
D O I
10.1161/01.STR.0000106915.83041.0A
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose - Transcranial Doppler (TCD) monitoring for asymptomatic cerebral emboli is currently limited to short recordings by equipment size, restricting its clinical usefulness. We have developed a first ambulatory TCD system, evaluated it in at-risk patient groups, and used it to study the pattern of embolization in patients with symptomatic carotid stenosis. Methods - The system comprises an 18 x 11.5 x 3.2 cm battery-powered Doppler unit ( 425 g) and a 13-mm servo-controlled 2 MHz transducer probe. The quadrature raw Doppler signal is stored on flash-disk. An autosearch algorithm restores vessel insonation should signal quality fall. Initial evaluation was in 20 ambulatory stroke patients. Subsequently, 12 recently symptomatic carotid patients had recordings for greater than or equal to5 hours. Results - Recordings were well tolerated and a median of 96% of Doppler signal was suitable for analysis. Embolic signals were detected in 11 of the 12 symptomatic carotid patients. There was marked temporal variability in embolization and prolonging the recording increased the yield of embolic signal positive patients from 58% at 30 minutes to 92% at 150 minutes. In 3 subjects with frequent embolic signals, significant temporal clustering of embolic signals was observed. Conclusions - We have developed the first ambulatory TCD system. Good-quality recordings of greater than or equal to5 hours can be obtained. In view of the demonstrated temporal variability in embolization, this technique is likely to improve the predictive value of recording for asymptomatic embolic signals and may be particularly useful in patients in whom embolic signals are relatively infrequent, such as those with asymptomatic carotid stenosis and atrial fibrillation.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 20 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]  
*AIUM, 1996, J ULTRAS MED, V15, pS1
[3]  
Bioeffects considerations for the safety of diagnostic ultrasound, 1988, J ULTRAS MED, V7, pS1
[4]   Evaluation of new online automated embolic signal detection algorithm, including comparison with panel of international experts [J].
Cullinane, M ;
Reid, G ;
Dittrich, R ;
Kaposzta, Z ;
Ackerstaff, R ;
Babikian, V ;
Droste, DW ;
Grossett, D ;
Siebler, M ;
Valton, L ;
Markus, HS .
STROKE, 2000, 31 (06) :1335-1341
[5]   Asymptomatic embolization in subjects with atrial fibrillation not taking anticoagulants - A prospective study [J].
Cullinane, M ;
Wainwright, R ;
Brown, A ;
Monaghan, M ;
Markus, HS .
STROKE, 1998, 29 (09) :1810-1815
[6]   Variability in occurrence of embolic signals in long term transcranial Doppler recordings [J].
Droste, DW ;
Decker, W ;
Siemens, HJ ;
Kaps, M ;
SchulteAltedorneburg, G .
NEUROLOGICAL RESEARCH, 1996, 18 (01) :25-30
[7]   Switching off embolization from symptomatic carotid plaque using S-nitrosoglutathione [J].
Kaposzta, Z ;
Martin, JF ;
Markus, HS .
CIRCULATION, 2002, 105 (12) :1480-1484
[8]   How good is intercenter agreement in the identification of embolic signals in carotid artery disease? [J].
Markus, H ;
Bland, JM ;
Rose, G ;
Sitzer, M ;
Siebler, M .
STROKE, 1996, 27 (07) :1249-1252
[9]  
Markus H, 2000, CIRCULATION, V102, P826
[10]   Transcranial Doppler ultrasound [J].
Markus, HS .
BRITISH MEDICAL BULLETIN, 2000, 56 (02) :378-388