Comparison of tissue impedance measurements with nerve fiber architecture in human telencephalon: value in identification of intact subcortical structures

被引:15
作者
Axer, H [1 ]
Stegelmeyer, J [1 ]
von Keyserlingk, DG [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Anat 1, Dept Anat 1, D-52057 Aachen, Germany
关键词
impedance; stereotaxis; nerve fiber; texture; 1,1 '-dilinoleyl-3,3,3 ',3 '-tetramethylindocarbocyanine perchlorate confocal imaging;
D O I
10.3171/jns.1999.90.5.0902
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. After establishing the general possibility of real-time impedance monitoring during stereotactic procedures in five postmortem human brains, the authors proceeded to analyze the value of impedance measurements in intact cerebral structures. Methods. The authors performed impedance measurements at 24 selected points in the brain of a human cadaver and labeled the points by using 1,1'-dilinoleyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI). The texture of the nerve fibers was visualized using confocal laser scanning microscopy, which allowed classification of distinct anatomical regions in the white and gray matter according to their fiber structure (density, direction, structure, and diameter). These regions displayed characteristic differences in impedances according to their fiber structure at frequencies between 8000 and 10,000 Hz. Differences in tissue impedance are not removed, although they are shifted to higher values by fixation with formalin. The reference frequency used in clinical environments (50,000 Hz) is not useful for distinct localization purposes. Finally, the orientation of the electrode in relation to the tissue is a crucial factor. Conclusions. It should be possible to draw conclusions about the correct position of the stereotactic needle on the basis of the proposed location, the texture of the fibers (orientation and density), and the orientation of the: electrode.
引用
收藏
页码:902 / 909
页数:8
相关论文
共 16 条
[1]  
[Anonymous], FUNCTIONAL STEREOTAC
[2]  
BAKER GE, 1993, METHOD CELL BIOL, V38, P325
[3]   VALUE OF SERIAL STEREOTACTIC BIOPSIES AND IMPEDANCE MONITORING IN THE TREATMENT OF DEEP BRAIN-TUMORS [J].
BROGGI, G ;
FRANZINI, A .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1981, 44 (05) :397-401
[4]   MEASUREMENT OF TISSUE IMPEDANCE IN CONJUNCTION WITH COMPUTED TOMOGRAPHY-GUIDED STEREOTAXIC BIOPSIES [J].
BULLARD, DE ;
MAKACHINAS, TT .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1987, 50 (01) :43-51
[6]   CORRELATION OF CT AND MR WITH IMPEDANCE MONITORING AND HISTOPATHOLOGY IN STEREOTAXIC BIOPSIES [J].
GORECKI, J ;
DOLAN, EJ ;
TASKER, RR ;
KUCHARCZYK, W .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1990, 17 (02) :184-189
[8]  
Hobza V, 1995, Sb Ved Pr Lek Fak Karlovy Univerzity Hradci Kralove, V38, P33
[9]   FLUORESCENT CARBOCYANINE DYES ALLOW LIVING NEURONS OF IDENTIFIED ORIGIN TO BE STUDIED IN LONG-TERM CULTURES [J].
HONIG, MG ;
HUME, RI .
JOURNAL OF CELL BIOLOGY, 1986, 103 (01) :171-187
[10]  
LAITINEN LV, 1967, CONFIN NEUROL, V29, P197