Purpose. This study was done to evaluate the hemodynamic effects of a pumpless implantable extracorporeal membrane oxygenation (ECMO) circuit between the right ventricle (RV) and left atrium (LA) in a chronic canine model with an RV pressure overload. Method. We created a model of right-sided heart failure by pulmonary artery banding in ten dogs for a duration of more than 3 months. After demonstrating that the RV pressure increased, a bypass circuit was created between the RV and LA with an in-line oxygenator. Both the hemodynamics and gas exchange were measured. Results. The effects of a pulmonary bypass in nine dogs were studied. Approximately half of the RV output was passively shunted through the bypass circuit, and a marked reduction in the RV pressure and recovery from right heart failure were observed. After a complete ligation of the main pulmonary artery, five of the nine dogs survived more than 6h. The RV pressure did not change significantly, but the cardiac output and blood pressure gradually decreased. The blood gas state was sufficiently maintained throughout the experiment. Conclusion. The present study indicates the hemodynamic benefit of a partial pumpless ECMO system in dogs with chronically pressure-overloaded right heart failure; however, the experimental preparation of the total pumpless ECMO circuit proved to be unstable.
引用
收藏
页码:861 / 868
页数:8
相关论文
共 26 条
[1]  
BODELL BR, 1965, JAMA-J AM MED ASSOC, V191, P125
[2]   PULMONARY-ARTERY CONSTRICTION PRODUCES A GREATER RIGHT VENTRICULAR DYNAMIC AFTERLOAD THAN LUNG MICROVASCULAR INJURY IN THE OPEN CHEST DOG [J].
CALVIN, JE ;
BAER, RW ;
GLANTZ, SA .
CIRCULATION RESEARCH, 1985, 56 (01) :40-56
[3]  
CHABOT F, 1995, PRESSE MED, V24, P1574
[4]   Platelet and leukocyte activation and design consequences for thoracic artificial lungs [J].
Cook, KE ;
Maxhimer, J ;
Leonard, DJ ;
Mavroudis, C ;
Backer, CL ;
Mockros, LF .
ASAIO JOURNAL, 2002, 48 (06) :620-630
[5]  
COOK KE, 1996, ASAIO J, V42, P604
[6]   LUNG TRANSPLANTATION [J].
COOPER, JD .
ANNALS OF THORACIC SURGERY, 1989, 47 (01) :28-44
[7]  
FAZZALARI FL, 1994, ASAIO J, V40, P728
[8]  
FURSTER V, 1984, CIRCULATION, V70, P580
[9]   Modeling flow effects on thrombotic deposition in a membrane oxygenator [J].
Gartner, MJ ;
Wilhelm, CR ;
Gage, KL ;
Fabrizio, MC ;
Wagner, WR .
ARTIFICIAL ORGANS, 2000, 24 (01) :29-36
[10]   Design of an artificial lung compliance chamber for pulmonary replacement [J].
Haft, JW ;
Bull, JL ;
Rose, R ;
Katsra, J ;
Grotberg, JB ;
Bartlett, RH ;
Hirschl, RB .
ASAIO JOURNAL, 2003, 49 (01) :35-40