Quadruple pads approach for external cardioversion of atrial fibrillation

被引:25
作者
Marrouche, NF
Bardy, GH
Frielitz, HJ
Günther, J
Brachmann, J
机构
[1] Klinikum Coburg, Med Klin Kardiol 2, Coburg, Germany
[2] Univ Washington, Med Ctr, Dept Med, Seattle, WA 98195 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 09期
关键词
atrial fibrillation; high energy cardioversion;
D O I
10.1046/j.1460-9592.2001.01321.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study examined the alternative of transthoracic quadruple pads shock delivery of two simultaneous 360-J shocks to convert refractory AF in patients failing standard external cardioversion. Forty-six patients (mean age 58 +/- 11 years, 23 men) with chronic AF (duration 14 +/- 17 months, range 1-60 months) were included. The left atrial diameter was 47 +/- 7 mm. The left ventricular ejection fraction was 59 +/- 11%. Antiarrhythmic drugs had failed to convert 44 (96%) of these patients. All patients underwent conventional external transthoracic cardioversion with pads applied in the antero-apical position using energy settings of 200 and 360 J, consecutively. In all patients who failed conventional cardioversion, quadruple pads were applied, Quadruple pads consisted of four pads, two in the antero-posterior position and two in a second apex-posterior position. Standard cardioversion to sin us rhythm was successful in 19 (41%) patients after use of a single 200-J shock and an additional 8 (17%) after a single 360-J shock. The total success rate was 58% after conventional cardioversion. The quadruple pads were successful in 14 (74%) of the remaining 19 patients. Four of the five patients who failed the quadruple pads approach subsequently also failed internal cardioversion. Thus, the cardioversion success rate was increased from 48% using the conventional approach to 89% using the quadruple pads approach. Quadruple pads external cardioversion is highly effective in converting chronic AF refractory to standard shock protocols to sinus rhythm. Moreover, the failure of the quadruple pads approach seems to predict poor response to internal cardioversion.
引用
收藏
页码:1321 / 1324
页数:4
相关论文
共 23 条
[1]  
Alt E, 1997, EUR HEART J, V18, P1796
[2]   Effect of electrode position on outcome of low-energy intracardiac cardioversion of atrial fibrillation [J].
Alt, E ;
Schmitt, C ;
Ammer, R ;
Plewan, A ;
Evans, F ;
Pasquantonio, J ;
Ideker, T ;
Lehmann, G ;
Putter, K ;
Schomig, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (05) :621-625
[3]   ROLE OF PROPHYLACTIC ANTICOAGULATION FOR DIRECT-CURRENT CARDIOVERSION IN PATIENTS WITH ATRIAL-FIBRILLATION OR ATRIAL-FLUTTER [J].
ARNOLD, AZ ;
MICK, MJ ;
MAZUREK, RP ;
LOOP, FD ;
TROHMAN, RG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (04) :851-855
[4]   Effects of oral propafenone administration before electrical cardioversion of chronic atrial fibrillation: A placebo-controlled study [J].
Bianconi, L ;
Mennuni, M ;
Lukic, V ;
Castro, A ;
Chieffi, M ;
Santini, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (03) :700-706
[5]   Double external direct-current shocks for refractory atrial fibrillation [J].
Bjerregaard, P ;
El-Shafei, A ;
Janosik, DL ;
Schiller, L ;
Quattromani, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) :972-+
[6]   External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements [J].
Botto, GL ;
Politi, A ;
Bonini, W ;
Broffoni, T ;
Bonatti, R .
HEART, 1999, 82 (06) :726-730
[7]   Oral amiodarone increases the efficacy of direct-current cardioversion in restoration of sinus rhythm in patients with chronic atrial fibrillation [J].
Capucci, A ;
Villani, GQ ;
Aschieri, D ;
Rosi, A ;
Piepoli, MF .
EUROPEAN HEART JOURNAL, 2000, 21 (01) :66-73
[8]  
DALZELL GWN, 1991, Q J MED, V78, P85
[9]   ECHOCARDIOGRAPHIC AND CLINICAL PREDICTORS FOR OUTCOME OF ELECTIVE CARDIOVERSION OF ATRIAL-FIBRILLATION [J].
DITTRICH, HC ;
ERICKSON, JS ;
SCHNEIDERMAN, T ;
BLACKY, AR ;
SAVIDES, T ;
NICOD, PH .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (03) :193-197
[10]   RELATION BETWEEN ECHOCARDIOGRAPHICALLY DETERMINED LEFT ATRIAL SIZE AND ATRIAL-FIBRILLATION [J].
HENRY, WL ;
MORGANROTH, J ;
PEARLMAN, AS ;
CLARK, CE ;
REDWOOD, DR ;
ITSCOITZ, SB ;
EPSTEIN, SE .
CIRCULATION, 1976, 53 (02) :273-279