Multivariate calibration of polycyclic aromatic hydrocarbon mixtures from excitation-emission fluorescence spectra

被引:138
作者
Beltrán, JL [1 ]
Ferrer, R [1 ]
Guiteras, J [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
multivariate calibration; partial least squares; PARAFAC; polycyclic aromatic hydrocarbons; EEM fluorescence;
D O I
10.1016/S0003-2670(98)00420-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The excitation-emission fluorescence spectra (EEM) of mixtures of 10 polycyclic aromatic hydrocarbons (PAHs) have been analyzed using different multivariate calibration procedures (partial least squares regression, PLSR; and parallel factor analysis, PARAFAC). The compounds studied were anthracene, benz[a]anthracene, benzo[a]pyrene, chrysene, phenanthrene, fluoranthene, fluorene, naphthalene, perylene and pyrene. Several algorithms (PARAFAC, PLS1, PLS2, Tri-PLS1 and Tri-PLS2) were tested for the quantification of these compounds from the EEM spectra of a set of standards, at ng ml(-1) levels, The best results were obtained by the application of a three-way multivariate calibration method (Tri-PLS2). This method was selected for the determination of samples of tap and mineral waters spiked with all these PAHs. Excitation and emission wavelength ranges were between 240 and 300 nm and 310 and 478 nm, respectively. In the working conditions, an EEM spectrum covering this range could be recorded in about 2 min. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:311 / 319
页数:9
相关论文
共 21 条
[1]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[2]  
Bjorseth A., 1983, HDB POLYCYCLIC AROMA
[3]   Single measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water .2. Calibration and quantitation of naphthalene and styrene [J].
Booksh, KS ;
Muroski, AR ;
Myrick, ML .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3539-3544
[4]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[5]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
[6]  
2-3
[7]   FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY WITH AN INTENSIFIED DIODE-ARRAY DETECTOR [J].
CECIL, TL ;
RUTAN, SC .
JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2) :495-503
[8]   A STATISTICAL VIEW OF SOME CHEMOMETRICS REGRESSION TOOLS [J].
FRANK, IE ;
FRIEDMAN, JH .
TECHNOMETRICS, 1993, 35 (02) :109-135
[9]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[10]   APPLICATION OF THE METHOD OF RANK ANNIHILATION TO FLUORESCENT MULTICOMPONENT MIXTURES OF POLYNUCLEAR AROMATIC-HYDROCARBONS [J].
HO, CN ;
CHRISTIAN, GD ;
DAVIDSON, ER .
ANALYTICAL CHEMISTRY, 1980, 52 (07) :1071-1079