Mammography in 53,803 women from the New Hampshire Mammography Network

被引:118
作者
Poplack, SP
Tosteson, AN
Grove, MR
Wells, WA
Carney, PA
机构
[1] Dartmouth Hitchcock Med Ctr, Dept Radiol, Lebanon, NH 03756 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Community & Family Med, Lebanon, NH 03756 USA
[3] Dartmouth Hitchcock Med Ctr, Dept Pathol, Lebanon, NH 03756 USA
关键词
breast neoplasms; radiography; cancer screening; diagnostic radiology; observer performance;
D O I
10.1148/radiology.217.3.r00dc33832
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To describe measures of mammography performance in a geographically defined population and evaluate the interpreter's use of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: Mammographic data from 47,651 screening and 6,152 diagnostic examinations from November 1, 1996, to October 31, 1997, were linked to 1,572 pathologic results. Mammographic outcomes were based on BI-RADS assessments and recommendations reported by the interpreting radiologist. The consistency of BI-RADS recommendations was evaluated. RESULTS: Screening mammography had a sensitivity of 72.4% (95% Cl: 66.4%, 78.4%), specificity of 97.3% (95% Cl: 97.25%, 97.4%), and positive predictive value of 10.6% (95% Cl: 9.1%, 12.2%). Diagnostic mammography had higher sensitivity, 78.1% (95% Cl: 71.9%, 84.3%); lower specificity, 89.3% (950/0 Cl: 88.5%, 90.1%); and better positive predictive value, 17.1% (95% Cl: 14.5%, 19.8%). The cancer detection rate with screening mammography was 3.3 per 1.000 women, with a biopsy yield of 22.4%, whereas the interval cancer rate was 1.2 per 1,000. Nearly 80% of screening-detected invasive malignancies were node negative. The recall rate for screening mammography was 8.3%. Ultrasonography was used in 3.5% of screening and 17.5% of diagnostic examinations. BI-RADS recommendations were generally consistent, except for probably benign assessments. CONCLUSION: The sensitivity of screening mammography in this population-based sample is lower than expected, although other performance indicators are commendable. BI-RADS "probably benign" assessments are commonly misused.
引用
收藏
页码:832 / 840
页数:9
相关论文
共 43 条
[1]   MAMMOGRAPHIC SCREENING AND MORTALITY FROM BREAST-CANCER - THE MALMO MAMMOGRAPHIC SCREENING TRIAL [J].
ANDERSSON, I ;
ASPERGREN, K ;
JANZON, L ;
LANDBERG, T ;
LINDHOLM, K ;
LINELL, F ;
LJUNGBERG, O ;
RANSTAM, J ;
SIGFUSSON, B .
BRITISH MEDICAL JOURNAL, 1988, 297 (6654) :943-948
[2]  
[Anonymous], 1988, Periodic screening for breast cancer: The health insurance plan project and its sequel, 1963-1986
[3]  
[Anonymous], [No title captured]
[4]   Breast cancer surveillance consortium: A national mammography screening and outcomes database [J].
BallardBarbash, R ;
Taplin, SH ;
Yankaskas, BC ;
Ernster, VL ;
Rosenberg, RD ;
Carney, PA ;
Barlow, WE ;
Geller, BM ;
Kerlikowske, K ;
Edwards, BK ;
Lynch, CF ;
Urban, N ;
Key, CR ;
Poplack, SP ;
Worden, JK ;
Kessler, LG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) :1001-1008
[5]   Variability in the interpretation of screening mammograms by US radiologists - Findings from a national sample [J].
Beam, CA ;
Layde, PM ;
Sullivan, DC .
ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (02) :209-213
[6]   ASSESSMENT OF RADIOLOGIC TESTS - CONTROL OF BIAS AND OTHER DESIGN CONSIDERATIONS [J].
BEGG, CB ;
MCNEIL, BJ .
RADIOLOGY, 1988, 167 (02) :565-569
[8]  
Braman D M, 1989, J Fla Med Assoc, V76, P1031
[9]   SCREENING MAMMOGRAPHY IN COMMUNITY PRACTICE - POSITIVE PREDICTIVE VALUE OF ABNORMAL FINDINGS AND YIELD OF FOLLOW-UP DIAGNOSTIC PROCEDURES [J].
BROWN, ML ;
HOUN, F ;
SICKLES, EA ;
KESSLER, LG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1373-1377
[10]   INTERVAL BREAST CANCERS IN THE SCREENING MAMMOGRAPHY PROGRAM OF BRITISH-COLUMBIA - ANALYSIS AND CLASSIFICATION [J].
BURHENNE, HJ ;
BURHENNE, LW ;
GOLDBERG, F ;
HISLOP, TG ;
WORTH, AJ ;
REBBECK, PM ;
KAN, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) :1067-1071