Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation - Insights from serial intravascular ultrasound analysis in the TAXUS II study

被引:88
作者
Aoki, J
Colombo, A
Dudek, D
Banning, AP
Drzewiecki, J
Zmudka, K
Schiele, F
Russell, ME
Koglin, J
Serruys, PW
机构
[1] Erasmus MC, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
[2] Univ Milan, Osped San Raffaele, I-20127 Milan, Italy
[3] Jagiellonian Univ, Krakow, Poland
[4] John Radcliffe Hosp, Oxford OX3 9DU, England
[5] PSK No 7 Zaklad Kardiol, Katowice, Poland
[6] Ctr Hosp Univ Jean Minjoz, Besancon, France
[7] Boston Sci Corp, Natick, MA USA
关键词
stents; remodeling; restenosis;
D O I
10.1161/CIRCULATIONAHA.105.558601
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - The purpose of this study was to evaluate long-term vascular responses as long as 2 years after implantation of polymer-based, paclitaxel-eluting stents in contrast to uncoated stents. Methods and Results - TAXUS II is a randomized, double-blind trial comparing slow-release (SR) and moderate-release (MR) TAXUS stents with bare-metal control stents (BMSs). One hundred sixty-one event-free patients ( SR, 43; MR, 41; and BMS, 77) underwent serial intravascular ultrasound (IVUS) analysis after the procedure and at 6 months and 2 years. At 2 years, neointimal responses continued to be significantly suppressed in the SR and MR groups when compared with the BMS group (BMS, 1.49 +/- 1.12 mm(2); SR, 0.94 +/- 0.76 mm(2) [ P = 0.004]; and MR, 1.06 +/- 0.90 mm(2) [P = 0.02]). Between 6 months and 2 years, the BMS group showed compaction of the neointima (Delta, - 0.22 +/- 1.05 mm(2) [P = 0.08]). In contrast, both the SR and MR groups exhibited an increase (Delta SR, 0.30 +/- 0.76 mm(2) (P = 0.01); MR, 0.41 +/- 0.94 mm(2) [P = 0.009]). Between 6 months and 2 years, the initial increase in plaque outside the stent regressed in the BMS and SR groups to levels comparable to those after the procedure, whereas expansive remodeling partially regressed in the MR group (Delta between after the procedure and 2 years BMS, - 0.34 +/- 1.28 mm(2) [ P = 0.05]; SR, - 0.02 +/- 1.40 mm(2) [ P = 0.93]; MR, 0.32 +/- 1.56 mm(2) [P = 0.27]). Conclusions - The 2-year follow-up demonstrates that neointimal suppression was dose independent and that this effect was still sustained at 2 years. However, the increase in area outside the stent seen at 6 months regressed to different extents in a dose-dependent manner at 2 years.
引用
收藏
页码:3876 / 3883
页数:8
相关论文
共 23 条
[1]   Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model [J].
Carter, AJ ;
Aggarwal, M ;
Kopia, GA ;
Tio, F ;
Tsao, PS ;
Kolata, R ;
Yeung, AC ;
Llanos, G ;
Dooley, L ;
Falotico, R .
CARDIOVASCULAR RESEARCH, 2004, 63 (04) :617-624
[2]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[3]   Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions - An intravascular ultrasound analysis [J].
Degertekin, M ;
Serruys, PW ;
Tanabe, K ;
Lee, CH ;
Sousa, JE ;
Colombo, A ;
Morice, MC ;
Ligthart, JMR ;
de Feyter, PJ .
CIRCULATION, 2003, 108 (22) :2747-2750
[4]   Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents -: Three-year results of the RAVEL trial [J].
Fajadet, J ;
Morice, MC ;
Bode, C ;
Barragan, P ;
Serruys, PW ;
Wijns, W ;
Constantini, CR ;
Guermonprez, JL ;
Eltchaninoff, H ;
Blanchard, D ;
Bartorelli, A ;
Laarman, GJ ;
Perin, MA ;
Sousa, JE ;
Schuler, G ;
Molnar, F ;
Guagliumi, G ;
Colombo, A ;
Hayashi, EB ;
Wülfert, E .
CIRCULATION, 2005, 111 (08) :1040-1044
[5]   Pathological analysis of local delivery of paclitaxel via a polymer-coated stent [J].
Farb, A ;
Heller, PF ;
Shroff, S ;
Cheng, L ;
Kolodgie, FD ;
Carter, AJ ;
Scott, DS ;
Froehlich, J ;
Virmani, R .
CIRCULATION, 2001, 104 (04) :473-479
[6]   Extracellular matrix changes in stented human coronary arteries [J].
Farb, A ;
Kolodgie, FD ;
Hwang, JY ;
Burke, AP ;
Tefera, K ;
Weber, DK ;
Wight, TN ;
Virmani, R .
CIRCULATION, 2004, 110 (08) :940-947
[7]   Five-year clinical follow-up after intracoronary radiation - Results of a randomized clinical trial [J].
Grise, MA ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Cloutier, DA ;
Leon, MB ;
Tripuraneni, P ;
Teirstein, PS .
CIRCULATION, 2002, 105 (23) :2737-2740
[8]   A novel approach to quantitative analysis of intra vascular ultrasound images [J].
Hamers, R ;
Bruining, N ;
Knook, M ;
Sabate, M ;
Roelandt, JRTC .
COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 :589-592
[9]   Chronic arterial responses to stent implantation: A serial intravascular ultrasound analysis of Palmaz-Schatz stents in native coronary arteries [J].
Hoffmann, R ;
Mintz, GS ;
Popma, JJ ;
Satler, LF ;
Pichard, AD ;
Kent, KM ;
Walsh, C ;
Mackell, P ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1134-1139
[10]   Three-year follow-up after implantation of metallic coronary-artery stents [J].
Kimura, T ;
Yokoi, H ;
Nakagawa, Y ;
Tamura, T ;
Kaburagi, S ;
Sawada, Y ;
Sato, Y ;
Yokoi, H ;
Hamasaki, N ;
Nosaka, H ;
Nobuyoshi, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :561-566