EEG localization accuracy improvements using realistically shaped head models

被引:101
作者
Cuffin, BN
机构
[1] Francis Bitter National Magnet Laboratory, Massachusetts Institute of Technology, Cambridge
关键词
D O I
10.1109/10.486287
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A model of the head must be used in making estimates of the locations of electrical sources in the brain using electroencephalograms (EEG's) measured on the scalp. In part, the accuracy of these estimates is dependent on how accurately the model represents the actual head. In most work performed to date, spherical models of the head have been used. This paper presents results in which the estimates of source location are made in realistically shaped head models. Techniques for accurately and conveniently developing realistically shaped head models from CT's, MRI's, Xrays, and/or physical measurements are also presented. Realistically shaped head models are developed for three subjects with electrical sources implanted at known locations in the brain. Localization accuracy is found to be significantly better in the realistically shaped head models than in spherical models if EEG's with good signal-to-noise ratio are used.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 17 条
[1]   LOCATION OF SOURCES OF EVOKED SCALP POTENTIALS - CORRECTIONS FOR SKULL AND SCALP THICKNESSES [J].
ARY, JP ;
KLEIN, SA ;
FENDER, DH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (06) :447-452
[2]   APPLICATION OF ELECTROMAGNETIC THEORY TO ELECTROCARDIOLOGY .2. NUMERICAL SOLUTION OF INTEGRAL EQUATIONS [J].
BARNARD, ACL ;
DUCK, IM ;
LYNN, MS ;
TIMLAKE, WP .
BIOPHYSICAL JOURNAL, 1967, 7 (05) :463-&
[3]   MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
COHEN, D ;
CUFFIN, BN ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, JG ;
SCHOMER, DL .
ANNALS OF NEUROLOGY, 1990, 28 (06) :811-817
[4]   EFFECTS OF LOCAL VARIATIONS IN SKULL AND SCALP THICKNESS ON EEGS AND MEGS [J].
CUFFIN, BN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (01) :42-48
[5]   A METHOD FOR LOCALIZING EEG SOURCES IN REALISTIC HEAD MODELS [J].
CUFFIN, BN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (01) :68-71
[6]   TESTS OF EEG LOCALIZATION ACCURACY USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
CUFFIN, BN ;
COHEN, D ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, J ;
SCHOMER, D .
ANNALS OF NEUROLOGY, 1991, 29 (02) :132-138
[7]   EFFECTS OF HEAD SHAPE ON EEGS AND MEGS [J].
CUFFIN, BN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :44-52
[8]   ACCURACY OF DIPOLE LOCALIZATION WITH A SPHERICAL HOMOGENEOUS MODEL [J].
GAUMOND, RP ;
LIN, JH ;
GESELOWITZ, DB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (01) :29-34
[9]   SURFACE EEG IN RELATION TO ITS SOURCES [J].
GEISLER, CD ;
GERSTEIN, GL .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1961, 13 (06) :927-&
[10]   ELECTRIC-DIPOLE TRACING IN THE BRAIN BY MEANS OF THE BOUNDARY ELEMENT METHOD AND ITS ACCURACY [J].
HE, B ;
MUSHA, T ;
OKAMOTO, Y ;
HOMMA, S ;
NAKAJIMA, Y ;
SATO, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (06) :406-414