Sensitivity advantage of swept source and Fourier domain optical coherence tomography

被引:1487
作者
Choma, MA [1 ]
Sarunic, MV [1 ]
Yang, CH [1 ]
Izatt, JA [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
D O I
10.1364/OE.11.002183
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present theoretical and experimental results which demonstrate the superior sensitivity of swept source ( SS) and Fourier domain (FD) optical coherence tomography (OCT) techniques over the conventional time domain (TD) approach. We show that SS- and FD-OCT have equivalent expressions for system signal-to-noise ratio which result in a typical sensitivity advantage of 20-30dB over TD-OCT. Experimental verification is provided using two novel spectral discrimination (SD) OCT systems: a differential fiber-based 800nm FD-OCT system which employs deep-well photodiode arrays, and a differential 1300 nm SS- OCT system based on a swept laser with an 87 nm tuning range. (C) 2003 Optical Society of America.
引用
收藏
页码:2183 / 2189
页数:7
相关论文
共 16 条
[1]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[2]  
CHOMA MA, 2003, IN PRESS OPT LETT
[3]   Spectral resolution and sampling issues in Fourier-transform spectral interferometry [J].
Dorrer, C ;
Belabas, N ;
Likforman, JP ;
Joffre, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (10) :1795-1802
[4]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[5]   Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser [J].
Golubovic, B ;
Bouma, BE ;
Tearney, GJ ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (22) :1704-1706
[6]   CHIRP OPTICAL COHERENCE TOMOGRAPHY OF LAYERED SCATTERING MEDIA [J].
Haberland, U. H. P. ;
Blazek, V. ;
Schmitt, H. J. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) :259-266
[7]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[10]   Wavelength-tuning interferometry of intraocular distances [J].
Lexer, F ;
Hitzenberger, CK ;
Fercher, AF ;
Kulhavy, M .
APPLIED OPTICS, 1997, 36 (25) :6548-6553