Effect of age on cerebral blood flow: Measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults

被引:184
作者
Buijs, PC
Krabbe-Hartkamp, MJ
Bakker, CJG
de Lange, EE
Ramos, LMP
Breteler, MMB
Mali, WPTM
机构
[1] Univ Utrecht Hosp, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Virginia, Hlth Sci Ctr, Dept Radiol, Charlottesville, VA 22908 USA
[3] Erasmus Univ, Sch Med, Dept Epidemiol & Biostat, NL-3000 DR Rotterdam, Netherlands
关键词
aging; brain; blood flow; cerebral blood vessels; flow dynamics; MR; magnetic resonance (MR); flow studies;
D O I
10.1148/radiology.209.3.9844657
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the normal values and effects of age and sex on total cerebral blood flow (CBF) as measured with ungated two-dimensional phase-contrast magnetic resonance (MR) angiography. MATERIALS AND METHODS: Volume flow rates in the basilar artery and both internal carotid arteries were measured on two-dimensional phase-contrast MR angiograms obtained in 250 subjects(age range, 19-88 years; mean age, 50 years) undergoing MR imaging because of indications other than cerebrovascular disease. Volume flow rates for-the th ree arteries were sum med to obtain the total CBF, and the values were analyzed in terms of age and sex. RESULTS: Mean total CBF was 616 mL/min +/- 143. There was a significant yearly decrease with age in total CBF of 4.8 mL/min (P < .001). Mean total CBF ranged from 748 mL/min +/- 121 to 474 mL/min +/- 105 in subjects aged 19-29 and 80-89 years respectively. No sex differences were found. Mean relative contributions of the right and left internal carotid arteries and the basilar artery to total CBF were 41%, 40% and 19%, respectively, with no substantial change due to age. CONCLUSION: Ungated two-dimensional phase-contrast MR angiography is a useful, noninvasive technique for assessing total CBF. By using this technique, a significant decrease in total CBF with age was demonstrated.
引用
收藏
页码:667 / 674
页数:8
相关论文
共 59 条
[1]   Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation [J].
Bakker, CJG ;
Kouwenhoven, M ;
Hartkamp, MJ ;
Hoogeveen, RM ;
Mali, WPTM .
MAGNETIC RESONANCE IMAGING, 1995, 13 (07) :959-965
[2]   Measuring blood flow by nontriggered 2D phase-contrast MR angiography [J].
Bakker, CJG ;
Hartkamp, MJ ;
Mali, WPTM .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :609-614
[3]   BLOOD-FLOW MEASUREMENTS IN THE AORTA AND MAJOR ARTERIES WITH MR VELOCITY MAPPING [J].
BOGREN, HG ;
BUONOCORE, MH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :119-130
[4]   CAROTID AND VERTEBRAL ARTERY BLOOD-FLOW IN LEFT-HANDED AND RIGHT-HANDED HEALTHY-SUBJECTS MEASURED WITH MR VELOCITY MAPPING [J].
BOGREN, HG ;
BUONOCORE, MH ;
GU, WZ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01) :37-42
[5]  
BUSWELL HR, 1993, RADIOLOGY, V189, P397
[6]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[7]   CEREBRAL BLOOD-FLOW AND CEREBROVASCULAR CO2 REACTIVITY IN STROKE-AGE NORMAL CONTROLS [J].
DAVIS, SM ;
ACKERMAN, RH ;
CORREIA, JA ;
ALPERT, NM ;
CHANG, J ;
BUONANNO, F ;
KELLEY, RE ;
ROSNER, B ;
TAVERAS, JM .
NEUROLOGY, 1983, 33 (04) :391-399
[8]   CORRELATION OF CINE MR VELOCITY-MEASUREMENTS IN THE INTERNAL CAROTID-ARTERY WITH COLLATERAL FLOW IN THE CIRCLE OF WILLIS - PRELIMINARY-STUDY [J].
DAVIS, WL ;
TURSKI, PA ;
GORBATENKO, KG ;
WEBER, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04) :603-609
[9]  
Dupui P, 1984, Monogr Neural Sci, V11, P131
[10]  
DVIS SM, 1981, J CEREB BLOOD FLO S1, V1, pS547