Incidence and Predictors of Debris Embolizing to the Brain During Transcatheter Aortic Valve Implantation

被引:156
作者
Van Mieghem, Nicolas M. [1 ]
El Faquir, Nahid [1 ]
Rahhab, Zouhair
Rodriguez-Olivares, Ramon [1 ]
Wilschut, Jeroen [1 ]
Ouhlous, Mohamed [2 ]
Galema, Tjebbe W. [1 ]
Geleijnse, Marcel L. [1 ]
Kappetein, Arie-Pieter [3 ]
Schipper, Marguerite E. I. [4 ]
de Jaegere, Peter P. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Cardiol, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Dept Radiol, NL-3015 CE Rotterdam, Netherlands
[3] Erasmus MC, Dept Cardiothorac Surg, NL-3015 CE Rotterdam, Netherlands
[4] Erasmus MC, Dept Pathol, NL-3015 CE Rotterdam, Netherlands
关键词
aortic stenosis; embolization; TAVR; ACADEMIC RESEARCH CONSORTIUM; END-POINT DEFINITIONS; CEREBRAL-ISCHEMIA; REPLACEMENT; STROKE; SILENT; RISK; COHORT;
D O I
10.1016/j.jcin.2015.01.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to identify variables associated with tissue fragment embolization during transcatheter aortic valve replacement (TAVR). BACKGROUND Brain magnetic resonance imaging and transcranial Doppler studies have revealed that cerebrovascular embolization occurs frequently during TAVR. Embolized material may be r thrombotic, tissue derived, or catheter (foreign material) fragments. METHODS A total of 81 patients underwent TAVR with a dual filter-based embolic protection device (Montage Dual Filter System, Claret Medical, Inc., Santa Rosa, California) deployed in the brachiocephalic trunk and left common carotid artery. Both balloon-expandable and self-expanding transcatheter heart valves (THVs) were used. Filters were retrieved after TAVR and sent for histopathological analysis. RESULTS Overall, debris was captured in 86% of patients. Captured material varied in size from 0.1 to 9.0 mm. Thrombotic material was found in 74% of patients and tissue-derived debris in 63%. Tissue fragments were found more often with balloon-expandable THVs (79% vs. 56%; p = 0.05). The embolized tissue originated from the native aortic valve leaflets, aortic wall, or left ventricular myocardium. On multivariable logistic regression analysis, balloon-expandable THVs (odds ratio: 7.315; 95% confidence interval: 1.398 to 38.289; p = 0.018) and cover index (odds ratio: 1.141; 95% confidence interval: 1.014 to 1.283; p = 0.028) were independent predictors of tissue embolization. CONCLUSIONS Debris is captured with filter-based embolic protection in the vast majority of patients undergoing TAVR. Tissue-derived material is found in 63% of cases and is more frequent with the use of balloon-expandable systems and more oversizing. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:718 / 724
页数:7
相关论文
共 21 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   Influence of Transcatheter Aortic Valve Replacement Strategy and Valve Design on Stroke After Transcatheter Aortic Valve Replacement [J].
Athappan, Ganesh ;
Gajulapalli, R. Dilip ;
Sengodan, Prasanna ;
Bhardwaj, Anju ;
Ellis, Stephen G. ;
Svensson, Lars ;
Tuzcu, Emin Murat ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (20) :2101-2110
[3]   Stroke Associated With Surgical and Transcatheter Treatment of Aortic Stenosis A Comprehensive Review [J].
Daneault, Benoit ;
Kirtane, Ajay J. ;
Kodali, Susheel K. ;
Williams, Mathew R. ;
Genereux, Philippe ;
Reiss, George R. ;
Smith, Craig R. ;
Moses, Jeffrey W. ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2143-2150
[4]   Prevalence of Silent Cerebral Ischemia in Paroxysmal and Persistent Atrial Fibrillation and Correlation With Cognitive Function [J].
Gaita, Fiorenzo ;
Corsinovi, Laura ;
Anselmino, Matteo ;
Raimondo, Cristina ;
Pianelli, Martina ;
Toso, Elisabetta ;
Bergamasco, Laura ;
Boffano, Carlo ;
Valentini, Maria Consuelo ;
Cesarani, Federico ;
Scaglione, Marco .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (21) :1990-1997
[5]   Clinical Outcomes After Transcatheter Aortic Valve Replacement Using Valve Academic Research Consortium Definitions A Weighted Meta-Analysis of 3,519 Patients From 16 Studies [J].
Genereux, Philippe ;
Head, Stuart J. ;
Van Mieghem, Nicolas M. ;
Kodali, Susheel ;
Kirtane, Ajay J. ;
Xu, Ke ;
Smith, Craig ;
Serruys, Patrick W. ;
Kappetein, A. Pieter ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (25) :2317-2326
[6]   Risk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation A Prospective Pilot Study With Diffusion-Weighted Magnetic Resonance Imaging [J].
Ghanem, Alexander ;
Mueller, Andreas ;
Naehle, Claas P. ;
Kocurek, Justine ;
Werner, Nikos ;
Hammerstingl, Christoph ;
Schild, Hans H. ;
Schwab, Joerg O. ;
Mellert, Fritz ;
Fimmers, Rolf ;
Nickenig, Georg ;
Thomas, Daniel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (14) :1427-1432
[7]   The Problem With Asymptomatic Cerebral Embolic Complications in Vascular Procedures What If They Are Not Asymptomatic? [J].
Gress, Daryl R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) :1614-1616
[8]   Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study [J].
Kahlert, Philipp ;
Al-Rashid, Fadi ;
Doettger, Philipp ;
Mori, Kathrine ;
Plicht, Bjoern ;
Wendt, Daniel ;
Bergmann, Lars ;
Kottenberg, Eva ;
Schlamann, Marc ;
Mummel, Petra ;
Holle, Dagny ;
Thielmann, Matthias ;
Jakob, Heinz G. ;
Konorza, Thomas ;
Heusch, Gerd ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2012, 126 (10) :1245-+
[9]   Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve Implantation A Diffusion-Weighted Magnetic Resonance Imaging Study [J].
Kahlert, Philipp ;
Knipp, Stephan C. ;
Schlamann, Marc ;
Thielmann, Matthias ;
Al-Rashid, Fadi ;
Weber, Marcel ;
Johansson, Uw ;
Wendt, Daniel ;
Jakob, Heinz G. ;
Forsting, Michael ;
Sack, Stefan ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2010, 121 (07) :870-878
[10]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1016/j.jacc.2012.09.001, 10.1093/ejcts/ezs533]