Selectivity and sensitivity of intramuscular and transcutaneous electromyography electrodes

被引:5
作者
Chae, J
Knutson, J
Hart, R
Fang, ZP
机构
[1] Case Western Reserve Univ, Ctr Phys Med & Rehabil, Metrohlth Med Ctr, Cleveland, OH 44109 USA
[2] Metrohlth Med Ctr, Dept Phys Med & Rehabil, Cleveland, OH USA
[3] Metrohlth Med Ctr, Dept Orthoped, Cleveland, OH USA
[4] Cleveland Vet Affair Med Ctr, Cleveland, OH USA
[5] NeuroControl Corp, Cleveland, OH USA
关键词
dynamic electromyography; intramuscular electromyography; transcutaneous electromyography;
D O I
10.1097/00002060-200105000-00010
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
We evaluated the differences in selectivity and sensitivity of intramuscular fine-wire electrodes and transcutaneous electrodes in detecting dynamic electromyography (EMG) signals from extensor digitorum (EDC) and extensor carpi radialis (ECR) muscles during isolated EDC and ECR contractions in two able-bodied subjects. Intramuscular fine-wire electrodes differentiated EDC and ECR EMG activities better than transcutaneous electrodes, and intramuscular fine-wire electrodes recorded higher amplitude signals than transcutaneous electrodes. Data suggest that intramuscular fine-wire electrodes are more selective and sensitive than transcutaneous electrodes in detecting EMG signals from adjacent forearm muscles.
引用
收藏
页码:374 / 379
页数:6
相关论文
共 20 条
[1]  
BAKER LL, 1988, CLIN ORTHOP RELAT R, P75
[2]  
BENHAMOU MAM, 1995, EXP BRAIN RES, V105, P432
[3]   Neuromuscular stimulation for upper extremity motor and functional recovery in acute hemiplegia [J].
Chae, J ;
Bethoux, F ;
Bohinc, T ;
Dobos, L ;
Davis, T ;
Friedl, A .
STROKE, 1998, 29 (05) :975-979
[4]   Comparison of discomfort associated with surface and percutaneous intramuscular electrical stimulation for persons with chronic hemiplegia [J].
Chae, J ;
Hart, R .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1998, 77 (06) :516-522
[5]   THE EFFECTS OF SKINFOLD THICKNESS ON THE SELECTIVITY OF SURFACE EMG [J].
DELABARRERA, EJ ;
MILNER, TE .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 93 (02) :91-99
[6]  
FIELDS RW, 1987, ARCH PHYS MED REHAB, V68, P407
[7]   Electromyogram-triggered neuromuscular stimulation for improving the arm function of acute stroke survivors: A randomized pilot study [J].
Francisco, G ;
Chae, J ;
Chawla, H ;
Kirshblum, S ;
Zorowitz, R ;
Lewis, G ;
Pang, S .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (05) :570-575
[8]  
GIROUX B, 1990, Electromyography and Clinical Neurophysiology, V30, P397
[9]  
HANSEN G, 1979, SCAND J REHABIL MED, V11, P189
[10]  
Hart R L, 1998, IEEE Trans Rehabil Eng, V6, P208, DOI 10.1109/86.681187