Echocardiographic measurement of fluid responsiveness

被引:96
作者
Charron, Cyril [1 ]
Caille, Vincent [1 ]
Jardin, Francois [1 ]
Vieillard-Baron, Antoine [1 ]
机构
[1] Univ Hosp Ambroise Pare, Assistance Publ Hop Paris, Med Intens Care Unit, Boulogne, France
关键词
echocardiography; fluid responsiveness; inferior vena cava; left ventricular stroke volume; preload responsiveness; septic shock; superior vena cava;
D O I
10.1097/01.ccx.0000224870.24324.cc
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Fluid responsiveness is a relatively new concept. It,enables the efficacy of volume expansion to be predicted before use, rather than assessed afterwards, thus avoiding inappropriate fluid infusion. Echocardiography is a fantastic noninvasive tool which can directly visualize the heart and assess cardiac function. Its use was long limited by the absence of accurate indices to diagnose hypovolemia and predict the effect of volume expansion. In the last few years, several French teams have used echocardiography to develop, new parameters of fluid responsiveness, taking advantage of its ability to monitor cardiac function beat by beat during the respiratory cycle. Recent findings In mechanically ventilated patients perfectly adapted to the respirator, respiratory variations in superior and inferior vena cava diameters and in left ventricular stroke volume have been validated as parameters of fluid responsiveness. In our opinion, the collapsibility index of the superior vena cava is the most reliable of these parameters, but does require transesophageal echocardiography. Summary Echocardiography has been widely demonstrated to predict fluid responsiveness accurately. This is now a complete and noninvasive tool able to accurately determine hemodynamic status in circulatory failure.
引用
收藏
页码:249 / 254
页数:6
相关论文
共 37 条
[1]  
Barbier C, 2004, INTENS CARE MED, V30, P1848, DOI 10.1007/s00134-004-2327-0
[2]   Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients [J].
Barbier, C ;
Loubières, Y ;
Schmit, C ;
Hayon, J ;
Ricôme, JL ;
Jardin, FO ;
Vieillard-Baron, A .
INTENSIVE CARE MEDICINE, 2004, 30 (09) :1740-1746
[3]   Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care [J].
Bendjelid, K ;
Romand, JA .
INTENSIVE CARE MEDICINE, 2003, 29 (03) :352-360
[4]   ECHOCARDIOGRAPHIC AND HEMODYNAMIC INDEXES OF LEFT-VENTRICULAR PRELOAD IN PATIENTS WITH NORMAL AND ABNORMAL VENTRICULAR-FUNCTION [J].
CHEUNG, AT ;
SAVINO, JS ;
WEISS, SJ ;
AUKBURG, SJ ;
BERLIN, JA .
ANESTHESIOLOGY, 1994, 81 (02) :376-387
[5]  
CHOLLEY B, 2005, INTENSIVE CARE 1116
[6]   Pulse pressure variations to predict fluid responsiveness: influence of tidal volume [J].
De Backer, D ;
Heenen, S ;
Piagnerelli, M ;
Koch, M ;
Vincent, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (04) :517-523
[7]   Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients [J].
Feissel, M ;
Badie, J ;
Merlani, PG ;
Faller, JP ;
Bendjelid, K .
CRITICAL CARE MEDICINE, 2005, 33 (11) :2534-2539
[8]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[9]   The respiratory variation in inferior vena cava diameter as a guide to fluid therapy [J].
Feissel, M ;
Michard, F ;
Faller, JP ;
Teboul, JL .
INTENSIVE CARE MEDICINE, 2004, 30 (09) :1834-1837
[10]   Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update [J].
Hollenberg, SM ;
Ahrens, TS ;
Annane, D ;
Astiz, ME ;
Chalfin, DB ;
Dasta, JF ;
Heard, SO ;
Martin, C ;
Napolitano, LM ;
Susla, GM ;
Totaro, R ;
Vincent, JL ;
Zanotti-Cavazzoni, S .
CRITICAL CARE MEDICINE, 2004, 32 (09) :1928-1948