Successful reduction of in-stent restenosis in long lesions using β-radiation -: Subanalysis from the reno registry

被引:4
作者
Baumgart, D
Bonan, R
Naber, C
Serruys, P
Colombo, A
Silber, S
Eeckhout, E
Urban, P
机构
[1] Univ Essen Gesamthsch, Essen, Germany
[2] Inst Cardiol Montreal, Montreal, PQ, Canada
[3] Heart Ctr Rotterdam, Rotterdam, Netherlands
[4] Colombus Hosp, Milan, Italy
[5] Mueller Hosp, Munich, Germany
[6] CHU Vaudois, CH-1011 Lausanne, Switzerland
[7] La Tour Hosp, Geneva, Switzerland
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 58卷 / 03期
关键词
beta-radiation; in-stent restenosis; long lesions;
D O I
10.1016/S0360-3016(03)01615-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Long lesions remain a challenging task in interventional cardiology, with a high propensity of restenosis, especially within the stented segment. Although intracoronary gamma-radiation has been proved to reduce diffuse in-stent restenosis in long lesions, such an effect remains to be determined using beta-radiation. Methods and Materials: Of 1098 consecutive patients at 46 European centers treated with localized beta-radiation (Sr-90, Novoste Beta-Cath System), 139 patients (mean age 61.5 +/- 10.7 years, 84% male, 22% with diabetes mellitus) with lesions treated using a >40-mm source length underwent radiation using a single 60-mm source train (34%) or a stepping/pullback procedure with a 30-mm (12%) or 40-mm (87%) source length after conventional interventional procedures. The mean lesion length was 35.3 +/- 17.9 nun. Results: Technical success was achieved in 96% of cases. Geographic miss was noted in 9 patients (6.5%). The reference (placebo) group was obtained from the Washington Hospital Center for In-Stent Restenosis Trial (WRIST) and the WRIST Trial for long lesions (LONG WRIST) studies by selecting the cases (94 patients) that required a dummy source length greater than or equal to13 seeds (or >51 mm in length). Statistically significant improvement was noted in late angiographic restenosis (34.7% vs. 76.5%, p < 0.0001), target vessel revascularization (14.9% vs. 60.6), and major adverse cardiac events (i.e., death, myocardial infarction, or total vessel revascularization) (17.9% vs. 64.9%, p < 0.0001) at 6 months in reference to the nonradiation group. Conclusion: This subanalysis from the Radiation in Europe with Novoste study confirms the safety and efficacy of beta-radiation combined with conventional interventional procedures in patients with diffuse, long, in-stent restenosis (C) 2004 Elsevier Inc.
引用
收藏
页码:817 / 827
页数:11
相关论文
共 23 条
[1]   Serial intravascular ultrasound of intracoronary γ-radiation assessment of the efficacy therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions [J].
Ahmed, JM ;
Mintz, GS ;
Waksman, R ;
Mehran, R ;
Leiboff, B ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Weissman, NJ .
CIRCULATION, 2001, 104 (08) :856-859
[2]  
Ahmed JM, 2001, CIRCULATION, V103, P188
[3]  
Crocker I, 2000, J Invasive Cardiol, V12, P643
[4]  
Crocker I, 2001, J Invasive Cardiol, V13, P782
[5]   The influence of stent length on clinical and angiographic outcome in patients undergoing elective stenting for native coronary artery lesions - Final results of the Magic 5L Study [J].
Foley, DP ;
Pieper, M ;
Wijns, W ;
Suryapranata, H ;
Grollier, G ;
Legrand, V ;
de Scheerder, I ;
Hanet, C ;
Puel, J ;
Mudra, H ;
Bonnier, HJRM ;
Colombo, A ;
Thomas, M ;
Probst, P ;
Morice, MC ;
Kleijne, J ;
Serruys, PW .
EUROPEAN HEART JOURNAL, 2001, 22 (17) :1585-1593
[6]   Source displacement during the cardiac cycle in coronary endovascular brachytherapy [J].
Giap, HB ;
Bendre, DD ;
Huppe, GB ;
Teirstein, PS ;
Tripuraneni, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01) :273-277
[7]   A novel quantitative method for evaluating diffuse in-stent narrowing at follow-up angiography [J].
Ishii, Y ;
van Weert, AWM ;
Hekking, E ;
de Marie, K ;
ter Horst, J ;
Oemrawsingh, PV ;
Reiber, JHC .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (03) :309-317
[8]   Edge stenosis and geographical miss following intracoronary gamma radiation therapy for in-stent restenosis [J].
Kim, HS ;
Waksman, R ;
Cottin, Y ;
Kollum, M ;
Bhargava, B ;
Mehran, R ;
Chan, RC ;
Mintz, GS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) :1026-1030
[9]  
Lansky A J, 1998, Indian Heart J, V50 Suppl 1, P104
[10]   Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting. [J].
Leon, MB ;
Teirstein, PS ;
Moses, JW ;
Tripuraneni, P ;
Lansky, AJ ;
Jani, S ;
Wong, SC ;
Fish, D ;
Ellis, S ;
Holmes, DR ;
Kerieakes, D ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (04) :250-256