Blood pressure dipping is reproducible in clinical practice

被引:33
作者
Ben-Dov, IZ [1 ]
Ben-Arieh, L [1 ]
Mekler, J [1 ]
Bursztyn, M [1 ]
机构
[1] Hadassah Univ Hosp, Dept Internal Med, IL-91120 Jerusalem, Israel
关键词
ambulatory blood pressure monitoring; dipping; circadian rhythm; reproducibility;
D O I
10.1097/00126097-200504000-00005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Blood pressure dipping pattern has clinical and prognostic consequences. However, reproducibility of night-time blood pressure fall during 24-h ambulatory blood pressure monitoring is considered limited. This limited reproducibility is possibly a result of inadequate day-night definitions. We retrospectively examined the reproducibility of blood pressure dipping in clinical practice, applying a method that accounts for sleep-awake states and does not rely on arbitrary day-night definitions. We also examined dipping repeatability in subjects with changing blood pressure. Methods Of 962 consecutive ambulatory measurements performed in our unit during a 3-year period, 100 patients (age 60 15) had a prior session, and were the subjects of this study. Based on patients' report we defined 'awake blood pressure' as the average of pressure recordings while the subject was awake, including night-time arousals, and 'sleep blood pressure' as the average of pressure recordings while the subject was sleeping, including afternoon naps. Results We found systolic blood pressure dipping not less reproducible than 24-h, awake- and sleep systolic blood pressure, as evaluated by both Pearson correlations (r=0.52 versus 0.5, 0.5, 0.49, respectively, P <= 0.0002 in all), and Bland-Altman repeatability. In a subgroup of 35 subjects (age 63 +/- 15) with at least 10 mmHg change in systolic blood pressure between the two sessions, systolic blood pressure dipping remained reproducible (r=0.45, P < 0.007). Conclusions When interpreted in a way that accounts for sleep-awake pattern, sleep-induced systolic blood pressure dipping in clinical practice is a very reproducible feature of ambulatory blood pressure monitoring, in accordance with its vital prognostic implications (c) 2005 Lippincott Williams & Wilkins.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 35 条
[1]   VALUE OF AMBULATORY BLOOD-PRESSURE MONITORING IN TYPE-I (INSULIN-DEPENDENT) DIABETIC-PATIENTS WITH INCIPIENT DIABETIC NEPHROPATHY [J].
BERRUT, G ;
HALLAB, M ;
BOUHANICK, B ;
CHAMEAU, AM ;
MARRE, M ;
FRESSINAUD, P .
AMERICAN JOURNAL OF HYPERTENSION, 1994, 7 (03) :222-227
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Bursztyn M, 1996, J HUM HYPERTENS, V10, P287
[4]   SIESTA AND AMBULATORY BLOOD-PRESSURE MONITORING - COMPARABILITY OF THE AFTERNOON NAP AND NIGHT SLEEP [J].
BURSZTYN, M ;
MEKLER, J ;
WACHTEL, N ;
BENISHAY, D .
AMERICAN JOURNAL OF HYPERTENSION, 1994, 7 (03) :217-221
[5]  
Casiglia E, 1996, J HYPERTENS, V14, P47
[6]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[7]   A QUANTITATIVE-ANALYSIS OF THE EFFECTS OF ACTIVITY AND TIME OF DAY ON THE DIURNAL-VARIATIONS OF BLOOD-PRESSURE [J].
CLARK, LA ;
DENBY, L ;
PREGIBON, D ;
HARSHFIELD, GA ;
PICKERING, TG ;
BLANK, S ;
LARAGH, JH .
JOURNAL OF CHRONIC DISEASES, 1987, 40 (07) :671-681
[8]   Target organ damage and non-dipping pattern defined by two sessions of ambulatory blood pressure monitoring in recently diagnosed essential hypertensive patients [J].
Cuspidi, C ;
Macca, G ;
Sampieri, L ;
Fusi, V ;
Severgnini, B ;
Michev, I ;
Salerno, M ;
Magrini, F ;
Zanchetti, A .
JOURNAL OF HYPERTENSION, 2001, 19 (09) :1539-1545
[9]   QUANTITATIVE-ANALYSIS OF THE 24-HOUR BLOOD-PRESSURE AND HEART-RATE PATTERNS IN YOUNG MEN [J].
DEGAUTE, JP ;
VANDEBORNE, P ;
LINKOWSKI, P ;
VANCAUTER, E .
HYPERTENSION, 1991, 18 (02) :199-210
[10]   How reliable is nighttime blood pressure dipping? [J].
Dimsdale, JE ;
Heeren, MM .
AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (05) :606-609