High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry

被引:61
作者
Flora, JW [1 ]
Hannis, JC [1 ]
Muddiman, DC [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
关键词
D O I
10.1021/ac0011282
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-mass accuracy is demonstrated using internal calibration for product ions produced by sustained off-resonance irradiation collision-induced dissociation (SORICID) of a 15-mer oligonucleotide, 5'-(CTG)(5)-3'. Internal calibration for this tandem MS experiment was accomplished using a dual electrospray ionization (ESI) source coupled with Fourier transform ion cyclotron resonance mass spectrometry, (FTICR-MS) utilizing hexapole accumulation and gated trapping, The pulse sequence entails injection, trapping, and gas-phase isolation of the precursor ion of interest followed by the SORI-CID of this ion and, subsequently, injection and trapping of the internal mass calibrant (i.e., poly(ethylene glycol) with a 1000 Da average mass). The product ions and the poly(ethylene glycol) ions are then simultaneously excited by a broadband frequency chirp excitation waveform and detected. This technique corrects for space-charge effects on the measurement of an ion's cyclotron frequency experienced when externally calibrated data are used. While external calibration for FTICR-MS can result in mass errors of greater than 100 ppm, this internal standardization method demonstrated significantly more consistent accurate mass measurements with average mass errors ranging from -1.2 to -3.2 ppm for the 15-mer oligonucleotide used in this study. This method requires limited modifications to ESI-FTICR mass spectrometers and is applicable for both positive and negative modes of ionization as well as other sample types (e.g., pharmaceuticals, proteins, etc.).
引用
收藏
页码:1247 / 1251
页数:5
相关论文
共 51 条
[1]  
Amster IJ, 1996, J MASS SPECTROM, V31, P1325
[2]  
ANDERSON GA, ICR2LS
[3]   Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions [J].
Bruce, JE ;
Anderson, GA ;
Brands, MD ;
Pasa-Tolic, L ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (05) :416-421
[4]   Exact mass measurements using a 7 Tesla Fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environment [J].
Burton, RD ;
Matuszak, KP ;
Watson, CH ;
Eyler, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1291-1297
[5]  
Cao P, 1998, RAPID COMMUN MASS SP, V12, P864, DOI 10.1002/(SICI)1097-0231(19980715)12:13<864::AID-RCM244>3.0.CO
[6]  
2-G
[7]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[8]   Routine part-per-million mass accuracy for high-mass ions: Space-charge effects in MALDI FT-ICR [J].
Easterling, ML ;
Mize, TH ;
Amster, IJ .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :624-632
[9]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[10]   ION FORMATION FROM CHARGED DROPLETS - ROLES OF GEOMETRY, ENERGY, AND TIME [J].
FENN, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :524-535