Peak capacity in gradient ultra performance liquid chromatography (UPLC)

被引:127
作者
Wren, SAC [1 ]
机构
[1] AstraZeneca, PAR&D, Analyt Dev, Macclesfield SK10 2NA, Cheshire, England
关键词
ultra performance liquid chromatography; gradient time; peak capacity;
D O I
10.1016/j.jpba.2004.12.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A prototype commercial instrument and 2.1 mm i.d. columns packed with 1.7 mu m porous particles have been used to measure peak capacity in ultra performance liquid chromatography (UPLC). Peak capacity was measured for a small molecule pharmaceutical as a function of gradient time, mobile phase flow rate, and column length. For very fast analysis, the highest peak capacity is obtained from a short column operating at high linear velocities. If an even higher peak capacity is required, a longer analysis time must be employed, and a point is reached where switching to a longer column becomes the best approach. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 14 条
[1]   EXAMINATION OF THEORETICAL PRINCIPLES OF GRADIENT ELUTION AS APPLIED TO REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SEPARATION OF PHENYLTHIOHYDANTOIN AMINO-ACIDS [J].
COHEN, KA ;
DOLAN, JW ;
GRILLO, SA .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :359-372
[2]   Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time I. Peak capacity limitations [J].
Dolan, JW ;
Snyder, LR ;
Djordjevic, NM ;
Hill, DW ;
Waeghe, TJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :1-20
[3]   Automated measurement of peak widths for the determination of peak capacity in complex chromatograms [J].
Lan, K ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :709-714
[4]  
Lippert JA, 1999, J MICROCOLUMN SEP, V11, P631, DOI 10.1002/(SICI)1520-667X(199911)11:9<631::AID-MCS1>3.3.CO
[5]  
2-9
[6]   Ultrahigh pressure reversed-phase liquid chromatography in packed capillary columns [J].
MacNair, JE ;
Lewis, KC ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :983-989
[7]   Effect of buffer on peak shape of peptides in reversed-phase high performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1038 (1-2) :77-84
[8]   Use of 1.5-μm porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography [J].
Mellors, JS ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 2004, 76 (18) :5441-5450
[9]  
Miller J. M., 1988, CHROMATOGRAPHY CONCE
[10]   Performance of an octadecylsilylated continuous porous silica column in polypeptide separations [J].
Minakuchi, H ;
Ishizuka, N ;
Nakanishi, K ;
Soga, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :83-90