Intracranial aneurysms: Detection with three-dimensional CT angiography with volume rendering - Comparison with conventional angiographic and surgical findings

被引:143
作者
Korogi, Y
Takahashi, M
Katada, K
Ogura, Y
Hasuo, K
Ochi, M
Utsunomiya, H
Abe, T
Imakita, S
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 860, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Radiol, Fujita, Japan
[3] Kyushu Univ, Fac Med, Dept Radiol, Fukuoka 812, Japan
[4] Nagasaki Univ, Sch Med, Dept Radiol, Nagasaki 852, Japan
[5] Fukuoka Univ, Sch Med, Dept Radiol, Fukuoka 81401, Japan
[6] Kurume Univ, Sch Med, Dept Radiol, Kurume, Fukuoka 830, Japan
[7] Natl Cardiovasc Ctr, Dept Radiol, Osaka, Japan
关键词
aneurysm; CT; intracranial; MR; cerebral blood vessels; computed tomography (CT); three-dimensional;
D O I
10.1148/radiology.211.2.r99ma02497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT;angiography may be a noninvasive technique;for; detection of asymptomatic unruptured or ruptured aneurysms.
引用
收藏
页码:497 / 506
页数:10
相关论文
共 21 条
[1]  
ALBERICO RA, 1995, AM J NEURORADIOL, V16, P1571
[2]  
BrantZawadzki M, 1997, AM J NEURORADIOL, V18, P1021
[3]  
Fleiss J. L, 1981, STAT METHODS RATES P, P212
[4]   PRACTICAL ISSUES OF EXPERIMENTAL ROC ANALYSIS - SELECTION OF CONTROLS [J].
GUR, D ;
KING, JL ;
ROCKETTE, HE ;
BRITTON, CA ;
THAETE, FL ;
HOY, RJ .
INVESTIGATIVE RADIOLOGY, 1990, 25 (05) :583-586
[5]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[6]  
HEINZ ER, 1995, AM J NEURORADIOL, V16, P1579
[7]  
Hope JKA, 1996, AM J NEURORADIOL, V17, P439
[8]   CT angiography with volume rendering: Advantages and applications in splanchnic vascular imaging [J].
Johnson, PT ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
RADIOLOGY, 1996, 200 (02) :564-568
[9]  
KATADA K, 1990, RADIOLOGY S, V177, P364
[10]   Intracranial aneurysms: Diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images [J].
Korogi, Y ;
Takahashi, M ;
Mabuchi, N ;
Nakagawa, T ;
Fujiwara, S ;
Horikawa, Y ;
Miki, H ;
OUchi, T ;
Shiga, H ;
Shiokawa, Y ;
Watabe, T ;
Furuse, M .
RADIOLOGY, 1996, 199 (01) :199-207