The long core needle with an end-cut technique for prostate biopsy:: Does it really have advantages when compared with standard needles?

被引:12
作者
Özden, E
Gögüs, C
Tulunay, Ö
Baltaci, S
机构
[1] Ankara Univ, Sch Med, Dept Urol, TR-06100 Ankara, Turkey
[2] Ankara Univ, Sch Med, Dept Pathol, TR-06100 Ankara, Turkey
关键词
prostate cancer; biopsy; end-cut needle; standard needle; comparison;
D O I
10.1016/j.eururo.2003.10.004
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the failure rate, core length and fragmentation rate for each different stroke length of the end-cut (BioPince) needle in order to show the performance of the needle for different stroke lengths and compare these with the standard side-notch needle. Methods: TRUS guided biopsy of the prostate was performed on 86 consecutive men between June 2002 and May 2003. The patients were randomized into two groups with 43 men in each group. Patients in group A underwent 8 core biopsy with the end-cut needle in different stroke lengths; 13, 23 and 33 mm respectively. Patients in group B underwent 8 core biopsy with the side-notch needle. The cores have been evaluated and compared for failure rates, core lengths, number of core lengths under 5 mm and fragmentation rates. Results: When the end-cut needle was used, a significant number of failure rates was noted; with an overall failure rate of 16%. The failure rates were 26% for 13 mm stroke length, 18% for 23 mm stroke length and 10% for 33 mm. stroke length respectively. These failure rates showed statistically significant difference from standard needle for overall and for every separate stroke length (p < 0.001 for all). Standard needle and the cores taken with 33 mm. stroke length of the end-cut needle had similar low fragmentation rates while 13 and 23 nun stroke lengths had higher rates. Of the overall cores taken by BioPince needle, 46/344 (13%) of the cores were shorter than 5 mm and this was significantly higher than the standard needle with 3/344 cores less than 5 mrn (p < 0.001). The end-cut needle when used with the 33 mm stroke length has improved the core length by 68% according to the standard side-notch needle. Conclusions: Our results showed that the performance of the end-cut needle worsens with decreased stroke lengths. The end-cut needle showed high failure rates which necessitates new punctures for taking a core. Additionally, the fragmentation rates are not lower than the standard needle and it has higher rates of taking small core samples. The only significant advantage of this needle over the standard needle is taking longer cores when it has been used at 33 mm stroke lengths. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 11 条
[1]   Three-dimensional computer-simulated prostate models: Lateral prostate biopsies increase the detection rate of prostate cancer [J].
Bauer, JJ ;
Zeng, JC ;
Weir, J ;
Zhang, W ;
Sesterhenn, IA ;
Connelly, RR ;
Mun, SK ;
Moul, JW .
UROLOGY, 1999, 53 (05) :961-967
[2]   Twelve prostate biopsies detect significant cancer volumes (&gt; 0.5 mL) [J].
Brössner, C ;
Bayer, G ;
Madersbacher, S ;
Kuber, W ;
Klingler, C ;
Pycha, A .
BJU INTERNATIONAL, 2000, 85 (06) :705-707
[3]   Systematic 5 region prostate biopsy is superior to sextant method for diagnosing carcinoma of the prostate [J].
Eskew, LA ;
Bare, RL ;
McCullough, DL .
JOURNAL OF UROLOGY, 1997, 157 (01) :199-202
[4]   A new core-biopsy instrument with an end-cut technique provides prostate biopsies with increased tissue yield [J].
Häggarth, L ;
Ekman, P ;
Egevad, L .
BJU INTERNATIONAL, 2002, 90 (01) :51-55
[5]   RANDOM SYSTEMATIC VERSUS DIRECTED ULTRASOUND GUIDED TRANS-RECTAL CORE BIOPSIES OF THE PROSTATE [J].
HODGE, KK ;
MCNEAL, JE ;
TERRIS, MK ;
STAMEY, TA .
JOURNAL OF UROLOGY, 1989, 142 (01) :71-75
[6]   Needle core length in sextant biopsy influences prostate cancer detection rate [J].
Iczkowski, KA ;
Casella, G ;
Seppala, RJ ;
Jones, GL ;
Mishler, BA ;
Qian, JQ ;
Bostwick, DG .
UROLOGY, 2002, 59 (05) :698-703
[7]   Patient tolerance of transrectal ultrasound-guided biopsy of the prostate [J].
Irani, J ;
Fournier, F ;
Bon, D ;
Gremmo, E ;
Dore, B ;
Aubert, J .
BRITISH JOURNAL OF UROLOGY, 1997, 79 (04) :608-610
[8]   The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer [J].
Norberg, M ;
Egevad, L ;
Holmberg, L ;
Sparen, P ;
Norlen, BJ ;
Busch, C .
UROLOGY, 1997, 50 (04) :562-566
[9]   The optimal systematic prostate biopsy scheme should include 8 rather than 6 biopsies: Results of a prospective clinical trial [J].
Presti, JC ;
Chang, JJ ;
Bhargava, V ;
Shinohara, K .
JOURNAL OF UROLOGY, 2000, 163 (01) :163-166
[10]   Extended peripheral zone biopsy schemes increase cancer detection rates and minimize variance in prostate specific antigen and age related cancer rates: Results of a community multi-practice study [J].
Presti, JC ;
O'Dowd, GJ ;
Miller, MC ;
Mattu, R ;
Veltri, RW .
JOURNAL OF UROLOGY, 2003, 169 (01) :125-129