Final results of a randomized trial comparing the MULTI-LINK stent with the Palmaz-Schatz stent for narrowings in native coronary arteries

被引:72
作者
Baim, DS
Cutlip, DE
Midei, M
Linnemeier, TJ
Schreiber, T
Cox, D
Kereiakes, D
Popma, JJ
Robertson, L
Prince, R
Lansky, AJ
Ho, KKL
Kuntz, RE
机构
[1] Brigham & Womens Hosp, Ctr Innovat Minimally Invas Therapy, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Med, Div Cardiovasc, Boston, MA 02115 USA
[3] Univ Rochester, Med Ctr, Rochester, NY 14642 USA
[4] St Josephs Med Ctr, Dept Cardiol, Baltimore, MD USA
[5] Guidant Corp, Santa Clara, CA USA
[6] St John Hosp & Med Ctr, Bloomfield Hills, MI USA
[7] Mid Carolina Cardiol, Charlotte, NC USA
[8] Ohio Heart Hlth Ctr, Cincinnati, OH USA
[9] Beth Israel Deaconess Med Ctr, Clin Res Ctr & Intervent Cardiol, Boston, MA 02215 USA
[10] Cardiovasc Data Anal Ctr, Boston, MA USA
[11] Lenox Hill Hosp, New York, NY 10021 USA
关键词
D O I
10.1016/S0002-9149(00)01308-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The MULTI-LINK (ML) stent is a novel second generation coronary stent. The ACS Multilink Stent Clinical Equivalence in De Novo Lesions Trial (ASCENT) randomized 1,040 patients with single, de novo native vessel lesions to treatment with the ML stent or the benchmark Palmaz-Schatz (PS) stent, to demonstrate that the ML stent was not inferior to (i.e., equivalent or better than) the PS stent in terms of target vessel failure by 9 months. Successful stent delivery was achieved in 98.8% versus 96.9% of patients, with a slightly lower postprocedural diameter stenosis (8% vs 10%, p = 0.04), and no difference in 30-day major adverse cardiac events (5.0% vs 6.5%) for the ML stent versus the PS stent. The primary end point of target vessel failure at 9 months was seen in 15.1% of ML-treated patients versus 16.7% of PS-treated patients, with the ML proving to be equal or superior to the PS stent (p <0.001 by test for equivalency). In a prespecified subset, angiographic restudy showed a nonsignificant trend for reduced ML restenosis (16.0% vs 22.1%). Thus, the ML stent showed excellent deliverability and acute results, with 9-month clinical and 6-month angiographic outcomes that were equivalent or better than the PS stent. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 19 条
[1]  
BLACKWELDER W, 1982, CONTR CLIN TRIALS, V3, P343
[2]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[3]   CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION [J].
ELLIS, SG ;
VANDORMAEL, MG ;
COWLEY, MJ ;
DISCIASCIO, G ;
DELIGONUL, U ;
TOPOL, EJ ;
BULLE, TM .
CIRCULATION, 1990, 82 (04) :1193-1202
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   A PREDICTIVE METHOD FOR ESTIMATING THE LATE ANGIOGRAPHIC RESULTS OF CORONARY INTERVENTION DESPITE INCOMPLETE ASCERTAINMENT [J].
KUNTZ, RE ;
KEANEY, KM ;
SENERCHIA, C ;
BAIM, DS .
CIRCULATION, 1993, 87 (03) :815-830
[6]   A clinical trial comparing three antithrombotic drug regimens after coronary-artery stenting [J].
Leon, MB ;
Baim, DS ;
Popma, JJ ;
Gordon, PC ;
Cutlip, DE ;
Ho, KKL ;
Giambartolome, A ;
Diver, DJ ;
Lasorda, DM ;
Williams, DO ;
Pocock, SJ ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (23) :1665-1671
[7]  
POPMA JJ, 1993, INTERVENTIONAL CARDI, P1052
[8]  
*SAS I, 1990, SAS STAT US GUID VER, P1351
[9]  
*SAS I INC, 1990, SAS STAT US GUID, P1071
[10]   Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts [J].
Savage, MP ;
Douglas, JS ;
Fischman, DL ;
Pepine, CJ ;
King, SB ;
Werner, JA ;
Bailey, SR ;
Overlie, PA ;
Fenton, SH ;
Brinker, JA ;
Leon, MB ;
Goldberg, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 337 (11) :740-747