Low-dose multislice CT of the thorax in follow-up of malignant lymphoma and extrapulmonary primary tumors

被引:36
作者
Dinkel, HP [1 ]
Sonnenschein, M [1 ]
Hoppe, H [1 ]
Vock, P [1 ]
机构
[1] Univ Bern, Inselspital, Dept Diagnost Radiol, CH-3010 Bern, Switzerland
关键词
multi-detector row CT; chest imaging; tumor follow-up; malignant lymphoma; cancer; staging; clinical use;
D O I
10.1007/s00330-002-1647-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the impact of low-dose multislice thoracic CT on image quality and lesion conspicuity in follow-up of patients with malignant lymphoma and extrapulmonary primary tumors. Forty consecutive patients with a history of malignant lymphoma or extrapulmonary malignant primaries who had undergone previous standard-dose thoracic spiral CT (120 kVp, 150 mAs, 8 mm) were subjected to low-dose multislice CT (15 mAs/rotation, 120 kVp, pitch 1.5, 4x2-mm collimation reconstructed to contiguous 8-mm slices. Image quality and lesion conspicuity were classified independently by two readers on a four-point ordinal scale (1=poor, 4=excellent). Mean image quality was significantly lower for low-dose CT, 2.35, than for standard-dose CT, 3.25 (p<0.001); however, all low-dose CT examinations were fully readable, none had to be repeated, and no lesions (including 51 lung lesions and 31 soft tissue lesions) remained undetected. Only in the apical lung did the lowered tube current significantly reduce lesion conspicuity. Even in pulmonary lesions smaller than 10 mm (n=21) lesion conspicuity did not significantly differ between standard and low-dose scans. Low-dose thoracic multislice CT based on a 90% reduction in dose compared with standard-dose techniques was not associated with impaired detection of suspicious lesions and may be useful in follow-up of malignant lymphoma and extrapulmonary tumors.
引用
收藏
页码:1241 / 1249
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 1990, ICRP PUBL
[2]  
BAUER B, 1998, RADIAT PROT DOSIM, V8, P1
[3]   Breast cancer risk following irradiation for Hodgkin's disease [J].
Clemons, M ;
Loijens, L ;
Goss, P .
CANCER TREATMENT REVIEWS, 2000, 26 (04) :291-302
[4]   Pulmonary nodules: Experimental and clinical studies at low-dose CT [J].
Diederich, S ;
Lenzen, H ;
Windmann, R ;
Puskas, Z ;
Yelbuz, TM ;
Henneken, S ;
Klaiber, T ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGY, 1999, 213 (01) :289-298
[5]   APPLICATION OF MATCHED PAIR PROCEDURES TO SITE-SPECIFIC DATA IN PERIODONTAL RESEARCH [J].
DONNER, A ;
ELIASZIW, M .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (10) :755-759
[6]   Breast cancer in women following supradiaphragmatic irradiation for Hodgkin's disease [J].
Gervais-Fagnou, DD ;
Girouard, C ;
Laperriere, N ;
Pintillie, M ;
Goss, PE .
ONCOLOGY, 1999, 57 (03) :224-231
[7]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[8]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[9]   A PC program for estimating organ dose and effective dose values in computed tomography [J].
Kalender, WA ;
Schmidt, B ;
Zankl, M ;
Schmidt, M .
EUROPEAN RADIOLOGY, 1999, 9 (03) :555-562
[10]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183