Box-Behnken design: An alternative for the optimization of analytical methods

被引:2561
作者
Ferreira, S. L. C. [1 ]
Bruns, R. E.
Ferreira, H. S.
Matos, G. D.
David, J. M.
Brandao, G. C.
da Silva, E. G. P.
Portugal, L. A.
dos Reis, P. S.
Souza, A. S.
dos Santos, W. N. L.
机构
[1] Univ Fed Bahia, Inst Quim, Campus Univ Ondina, BR-40170290 Salvador, BA, Brazil
[2] Univ Estadual Campinas, Inst Quim, BR-13084971 Sao Paulo, Brazil
[3] Univ Do Estado Bahia, BR-41195001 Salvador, BA, Brazil
关键词
Box-Behnken design : multivariate optimization; experimental design; analytical methods; desirability function; robustness; ONLINE PRECONCENTRATION SYSTEM; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID-EXTRACTION; SOLID-PHASE EXTRACTION; CLOUD POINT EXTRACTION; FACTORIAL-DESIGN; MULTIVARIATE OPTIMIZATION; GAS-CHROMATOGRAPHY; DOEHLERT MATRIX; LEAD DETERMINATION;
D O I
10.1016/j.aca.2007.07.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes fundamentals, advantages and limitations of the Box-Behnken design (BBD) for the optimization of analytical methods. It establishes also a comparison between this design and composite central, three-level full factorial and Doehlert designs. A detailed study on factors and responses involved during the optimization of analytical systems is also presented. Functions developed for calculation of multiple responses are discussed, including the desirability function, which was proposed by Derringer and Suich in 1980. Concept and evaluation of robustness of analytical methods are also discussed. Finally, descriptions of applications of this technique for optimization of analytical methods are presented. (C) 2007 Elsevier B.V.. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 98 条
[1]   Use of Box-Behnken design of experiments for the adsorption of verofix red using biopolymer [J].
Annadurai, G ;
Sheeja, RY .
BIOPROCESS ENGINEERING, 1998, 18 (06) :463-466
[2]   Factor optimization for phenol removal using activated carbon immobilized with Pseudomonas putida [J].
Annadurai, G ;
Juang, RS ;
Lee, DJ .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2002, 37 (02) :149-161
[3]  
Annadurai G, 2000, J CHIN INST CHEM ENG, V31, P609
[4]  
[Anonymous], 2005, ECL QUIM SAO PAULO
[5]  
[Anonymous], 2006, Statistical Design-Chemometrics
[6]   Experimental design to investigate factors affecting capillary zone electrophoresis [J].
Babu, CVS ;
Chung, BC ;
Yoo, YS .
ANALYTICAL LETTERS, 2004, 37 (12) :2485-2499
[7]   Development of a liquid-liquid extraction procedure for five 1,4-dihydropyridines calcium channel antagonists from human plasma using experimental design [J].
Baranda, AB ;
Etexbarria, N ;
Jiménez, RM ;
Alonso, RM .
TALANTA, 2005, 67 (05) :933-941
[8]   Statistical design-principal component analysis optimization of a multiple response procedure using cloud point extraction and simultaneous determination of metals by ICPOES [J].
Bezerra, Marcos A. ;
Bruns, Roy E. ;
Ferreira, Sergio L. C. .
ANALYTICA CHIMICA ACTA, 2006, 580 (02) :251-257
[9]   Doehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extraction [J].
Bezerra, MD ;
Conceiçao, ALB ;
Ferreira, SLC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) :798-803
[10]   Sonic spray ionization interface for liquid chromatography-mass spectrometry [J].
Björkman, HT ;
Edlund, PO ;
Jacobsson, SP .
ANALYTICA CHIMICA ACTA, 2002, 468 (02) :263-274