Reliability of motor-evoked potentials in the ADM muscle of older adults

被引:57
作者
Christie, Anita
Fling, Brett
Crews, Ryan T.
Mulwitz, Lauren A.
Kamen, Gary
机构
[1] Univ Massachusetts, Dept Kinesiol, Amherst, MA 01003 USA
[2] Rosalind Franklin Univ Med & Sci, CLEAR, N Chicago, IL USA
关键词
TMS; MEP; reliability; aging;
D O I
10.1016/j.jneumeth.2007.05.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of this study was to determine the reliability of motor-evoked potentials (MEPs) produced in the abductor digiti minimi (ADM) muscle of male and female older adults, both within and between sessions. The number of trials within a session required to obtain reliable results was also examined. The investigation was conducted on 30 elderly individuals (15 M, 15 F; mean age 76 years). With the ADM at rest, MEN were evoked at intensities of 1. 1, 1.3, and 1.5 times motor threshold (MT). Ten stimuli were delivered at each intensity, with 10-12 s between stimuli. The MEP responses were blocked with two, three, four, and five-stimuli means in each block. An intraclass correlation (ICC) reliability analysis of variance model was used to assess reliability of the MEP amplitude, using a variable number of trials per block. A subset of 10 subjects repeated the protocol following 20 min of rest to assess the reliability between sessions. As expected, MEP amplitudes were significantly higher as stimulus intensity increased. There were no significant differences between blocks, nor was there a significant gender effect. ICC reliability coefficients ranged between 0.09 with two trials per block and 0.97 with five trials per block. Between session reliability ranged from 0.65 to 0.83. Highly reliable MEP amplitudes can be obtained in older individuals using two blocks of TMS stimuli with five trials per block. Published by Elsevier B.V.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 20 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]   Reliability of the input-output properties of the cortico-spinal pathway obtained from transcranial magnetic and electrical stimulation [J].
Carroll, TJ ;
Riek, S ;
Carson, RG .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 112 (02) :193-202
[3]  
Cohen J., 1988, POWERSTATISTICALSCIE, DOI 10.4324/9780203771587
[4]   Motor-evoked potentials following imagery and limb disuse [J].
Crews, Ryan T. ;
Kamen, Gary .
INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2006, 116 (05) :639-651
[5]   Variability in the amplitude of skeletal muscle responses to magnetic stimulation of the motor cortex in man [J].
Ellaway, PH ;
Davey, NJ ;
Maskill, DW ;
Rawlinson, SR ;
Lewis, HS ;
Anissimova, NP .
ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 109 (02) :104-113
[6]  
GRIFFIN L, 2006, J ELECTROMYOGR KINES
[7]  
Haggard E.A., 1958, INTRACLASS CORRELATI
[8]  
Hetherington R, 1973, Res Q, V44, P113
[9]   Mechanisms responsible for the age-associated increase in coactivation of antagonist muscles [J].
Hortobágyi, T ;
DeVita, P .
EXERCISE AND SPORT SCIENCES REVIEWS, 2006, 34 (01) :29-35
[10]   Reliability of motor-evoked potentials during resting and active contraction conditions [J].
Kamen, G .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (09) :1574-1579